SPEC NO.
M T1 8 5GW 0 1 V. 0
PAGE
15/23
C. Optical specifications
Item Symbol Condition
Unit
Remark
Tr
- 1.5 4
Tf
- 3.5 6
Response time
Tr+Tf
θ= 0∘
- 5 10
ms
Note 4
Contrast ratio
CR
θ= 0∘
700 1000 -
Note 3,5
Top
CR≧10
CR≧5
70
75
80
85
-
Bottom
CR≧10
CR≧5
70
75
80
85
-
Left
CR≧10
75 85 -
Viewing angle
Right
CR≧10
75 85 -
deg.
Note 3,5,7
250 300
-
0.313
0.329
0.640
0.349
0.284
0.617
0.142
Color chromaticity(CIE)
θ= 0∘
-0.03
0.067
+0.03
Note 3
0.75 0.80 -
- -
2%
Note 1: Ambient temperature = 25°C.
Note 2: To be measured in dark room after backlight warm up 30 minutes.
Note 3: To be measured with a viewing cone of 2°by Topcon luminance meter BM-5A.
Note 4: Definition of response time:
The output signals of BM-7 are measured when the input signals are changed from “Black”
to “White” (falling time) and from “White” to “Black” (rising time), respectively. The response time
interval is between the 10% and 90% of amplitudes. Refer to figure as below.