Check packing condition and report any damage upon delivery.
Ensure the installation area is protected from steam and the machine is stable.
Connect the machine to the electrical supply via a suitable main switch and earthing system.
Connect the appliance to the water network using a shut-off valve and ensure compatibility.
Connect the drain hose to the drain line, considering height and pump requirements.
Ensure sufficient rinse aid and detergent levels; fill feed circuits manually.
Adjust detergent and rinse aid pump parameters for correct dosage amounts.
Specifies ambient temperature, altitude, and humidity requirements for safe operation.
Identifies keys and indicators on the control panel for operation.
Steps to turn on the machine, check supplies, and initiate the filling process.
Guidelines for loading racks, pre-cleaning dishes, and washing procedures.
How to choose the appropriate wash cycle and start the program.
Instructions to activate or deactivate the automatic cycle start function.
Procedure to shut down the machine and disconnect power.
Steps for safely removing and accessing the integral filter.
How to drain the machine's tank using the drain function.
Information on resin regeneration for water softeners and salt replenishment.
Steps for daily draining, power disconnection, and leaving the door ajar.
Periodic tasks for ensuring machine hygiene, including sanitizing treatments.
Procedures for cleaning the filter group and tank at the end of the day.
Steps to remove, clean, and reattach wash arms for nozzle maintenance.
Rinse not performed: check plumbing, water supply, or contact service.
Water drainage anomaly: check drain tube, filters, or contact service.
Boiler temperature reset anomaly: reset machine or contact technical service.
Tank filling time out: check connections, water supply, or contact service.
Tank thermometer anomaly (probe open): reset machine or contact technical service.
Tank thermometer anomaly (probe shorted): restart cycle or contact technical service.
Boiler thermometer anomaly (probe open): reset machine or contact technical service.
Boiler thermometer anomaly (probe shorted): restart cycle or contact technical service.
Boiler fill time out: check water supply, run cycle, or contact service.
Problem persists: disconnect power and contact technical service.
Safety thermostats tripped; contact a technical service centre.
Tank pressure switch detected incorrect water level; contact technical service.
Salt tank is empty, add salt as per section 4.9.
Resin regeneration is active, the wash cycle may take longer.
Adjust boiler and tank temperatures via specific menu options.
Access and modify various machine parameters like language, energy saving, and pump settings.
Guidelines for environmentally safe disposal of the appliance as WEEE.