- 64 -
07/ Error Information
LED Fan Error
Led Temp. Error
LED Timeout Error
LED Too Hot Off
When the fixture temperature reaches 72, it will automatically turn
off to protect the fixture.
Check whether the fan is not running.
Check whether the fan leads are installed in place or disconnected.
Check whether the fan is damaged.
Check whether there are obstacles in the fan operating range.
Check whether the fan circuit on the motherboard breaks down.
Check whether the component is damaged.
Check whether the fan is out of order.
Error codes are shown continuously in the display when the fixture fails and they will not
disappear until the fixture is repaired.
Check whether the temperature detecting board is normal.
Check whether the components of the temperature detecting board
are damaged.
Check whether the lead on the temperature detecting board is
installed in place or disconnected.