g) RF Gain
• 13 dB typically, frequency response less than 1 dB (60-85 W drive power for rated
output);
h) Mains Power Supply Voltage
• 85-132 VAC / 170-264 VAC (100, 110, 120, 200, 210, 220, 230 & 240 V nominal taps,
+10% -15% tolerance), 50-60 Hz, Single phase;
i) Mains Power Consumption
• Up to 3500 VA at rated output from 200/240 VAC mains supply;
• Up to 2400 VA at 1000W output from 100/120 VAC mains supply;
j) Safety and Electromagnetic Compatibility
• Complies with CE safety and electromagnetic compatibility requirements, as well as with
the US Federal Communications Commission (FCC) regulations;
k) Size & Weight (operating, excluding connected cables)
• WxDxH: 422x355x195 mm, 26.5 kg (16.7x14.0x7.7 inches, 58.5 lbs.);
l) Operating environments
• Temperature range: 0 to +50 degrees Celsius (32
o
F to 122
o
F);
• Relative air humidity: up to 95% @ +35 degrees Celsius (95
o
F);
• Height above sea level: up to 3050 m (10000 ft) without output deterioration.