EasyManua.ls Logo

Acson international AWSS30A - User Manual

Default Icon
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Technical Manual
WATER
COOLED
SINGLE SPLIT
AWSS30A AWSS40A
AWSS50A AWSS60A

Questions and Answers

  • L
    Laurie MartinezAug 1, 2025
    What to do if my Acson international AWSS30A Air Conditioner has insufficient cooling or heating?
    • K
      Kerry BrownAug 1, 2025
      If your Acson international Air Conditioner isn't cooling or heating adequately, consider the following: * Check the controller temperature setting and adjust it as needed. * The filter may be clogged; inspect and clean it. * A capillary tube might be restricting refrigerant flow; consider replacing it if it is restricted. * The reversing valve may be defective; check the reversing valve coil connection. * Ensure there are no restrictions of air and water flow. * There might be refrigerant leakage; inspect all piping bends and connections and repair any leaks. * Make sure no window or door is wide open; close any open windows or doors. * The unit may be under-sized.
  • J
    Joseph SmithAug 5, 2025
    Why is the remote control display light too dim on my Acson international Air Conditioner?
    • T
      Theresa AndersonAug 5, 2025
      If the remote control display light for your Acson international Air Conditioner is too dim: * The battery may be flat; replace it. * The batteries may not be properly positioned; check and reposition them.
  • P
    Paul HudsonAug 10, 2025
    Why Acson international Air Conditioner cannot start?
    • A
      andersonbarbaraAug 10, 2025
      If your Acson international Air Conditioner won't start, there are several potential causes: * The power supply plug may be disconnected. Check the plug and reconnect it if needed. * A circuit breaker may have tripped, or a fuse may have blown. Reset the circuit breaker or replace the fuse. * There may be an issue with the wiring connections. Check the wiring connections. If the problem continues, it is recommended to contact your installer.
  • J
    Jonathan MckenzieAug 14, 2025
    What to do if neither fan coil unit and compressor run in my Acson international AWSS30A?
    • R
      Richard MaysAug 14, 2025
      If neither the fan coil unit nor the compressor is running on your Acson international Air Conditioner, consider these potential issues: * A fuse may be blown, or the circuit breaker may be opened. Replace the blown fuse or reset the circuit breaker. * There might be an electrical circuit or motor winding issue, such as shorts or grounds. Investigate for possible overloading. * Wiring connections may be loose. Check and replace or tighten loose wiring connections. * The control system may be faulty.
  • J
    Justin DavilaAug 18, 2025
    How to fix noisy operation of Acson international Air Conditioner?
    • D
      Desiree SmithAug 18, 2025
      If your Acson international Air Conditioner is operating noisily, here are some things to check: * Loose bolts or screws: Tighten any that you find. * Rubber isolators: Ensure they are used for installation. * Water balance: Adjust for proper water flow rate to the unit. * Tubing: Check if it's touching the compressor or another surface, and readjust it by bending it slightly. * Fan (fan coil unit): May be knocking / hitting on its housing. * Compressor bearing: Noise may be due to a worn compressor bearing.
  • S
    Sonya BoltonAug 22, 2025
    What to do if the compressor does not operate in Acson international AWSS30A Air Conditioner?
    • C
      Christine MiddletonAug 22, 2025
      If the compressor in your Acson international Air Conditioner isn't working, here are a few things to investigate: * Check the capacitor (if available) and replace it if it's faulty. * Inspect wiring connections and replace or tighten them if necessary. * The high-pressure switch may have tripped; investigate possible causes like a clogged heat exchanger or insufficient water flow. If the compressor body is extremely hot, the overload will not reset until it has cooled down. If the compressor winding is grounded to the compressor shell, replace the compressor.
  • B
    bbeanAug 27, 2025
    How to increase water flow through heat exchanger in Acson international AWSS30A Air Conditioner?
    • P
      Pamela GainesAug 27, 2025
      To address insufficient water flow through the heat exchanger in your Acson international Air Conditioner: * Ensure all valves are fully opened. * If the circulating water pump is faulty, replace it. * Check for and clear any clogs in the water pipes or strainers.

Summary

Outdoor Unit Product Line-Up (AWSS)

Indoor Unit Product Line-Up (ACC-C)

2. FEATURES

Fault Codes and Indicators

Troubleshooting and System Checks

Common Faults and Solutions

Provides diagnostic steps for common operational issues.

Outdoor Unit Installation

Location and Mounting Procedures

Covers site requirements and how to mount the unit.

Piping and Electrical Connections

Indoor Unit ACC Installation

Site Survey and Installation Steps

Guides on preliminary checks and unit installation.

Indoor Unit Mounting and Drainage

Hanging and Drain Piping

Details on unit suspension and condensate drainage.

Indoor Unit AWM Installation

Refrigerant Piping and Flare Work

Refrigerant Piping Specifications

4. SOUND DATA (AWSS)

Sound Pressure Levels (ACC)

Sound Pressure Levels (ACK-A)

7. PERFORMANCE DATA

10. WIRING DIAGRAMS

Wiring Diagrams: ACC40;50;60 C & AWSS40;50;60 A

Wiring Diagrams: ACK Series

11. SERVICING & MAINTENANCE

Maintenance Procedures

Details regular cleaning and checks for unit longevity.

Pre-start Up Maintenance

Procedures for checking the unit after extended shutdown.

12. TROUBLESHOOTING

Common Faults and Solutions

Provides diagnostic steps for common operational issues.

13. EXPLODED VIEW & PART LIST

AWSS Series Exploded View and Parts

Shows breakdown and part numbers for AWSS units.

ACC Series Exploded View and Parts

ACK Series Exploded View and Parts

Acson international AWSS30A Specifications

General IconGeneral
BrandAcson international
ModelAWSS30A
CategoryAir Conditioner
LanguageEnglish

Related product manuals