Acson A5CK15CR - User Manual

Acson A5CK15CR
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Ceiling Cassette
Split Systems
ACK-A_B_C-2006
A5CK 20A/AR
A5CK 25A/AR
A5CK 30A/AR
A5CK 40A/AR
A5CK 50A/AR
A5CK 1 0C/CR
A5CK 15C/CR
A5CK 2 0C/CR
Models:
ISO 9002
REGISTERED

Questions and Answers

  • D
    Donald MackAug 4, 2025
    How to turn on Acson A5CK15CR Air Conditioner after power failure?
    • K
      Kenneth HumphreyAug 4, 2025
      If your Acson Air Conditioner unit does not resume after a power failure, turn on the unit with the wireless or wired controller.
  • D
    Dr. Debbie Ross DVMAug 8, 2025
    What to do if there is condensation on the front air grille of my Acson A5CK15CR?
    • R
      Robert ThompsonAug 8, 2025
      If there's condensation on the front air grille of your Acson Air Conditioner's indoor unit, it's likely due to air humidity or a set temperature that's too low. Try increasing the temperature setting and operating the unit at a high fan speed to resolve this.
  • J
    Jason HollandAug 13, 2025
    Why warm air does not come out of my Acson A5CK15CR on heating cycle?
    • T
      Tina DanielsAug 13, 2025
      If your Acson Air Conditioner is on a heating cycle and warm air isn't coming out, it's likely that the unit is in defrost mode. The heating operation will resume automatically after the defrost cycle ends.
  • K
    Keith MitchellAug 17, 2025
    What to do if Acson A5CK15CR compressor does not operate after starting?
    • M
      Melinda ThorntonAug 17, 2025
      The compressor in your Acson Air Conditioner is designed with a protection feature to prevent frequent starts. Please wait 3 to 4 minutes; the compressor should start operating on its own.
  • B
    Brian PinedaAug 21, 2025
    Why is the wireless controller display dim on my Acson Air Conditioner?
    • T
      Thomas BurgessAug 21, 2025
      If the wireless controller display for your Acson Air Conditioner is dim, the batteries may be discharged or not correctly inserted, or the assembly might not be good. Check the batteries and their placement.
  • K
    Kayla BarnesAug 26, 2025
    Why does my Acson Air Conditioner discharge airflow have a bad odor?
    • K
      Kevin WhiteAug 26, 2025
      If the discharge airflow from your Acson Air Conditioner has a bad odor, it may be due to cigarettes, smoke particles, perfume, or other substances that have adhered to the coil. Contact your nearest dealer for assistance.
  • M
    Monique RodriguezAug 30, 2025
    What causes hissing airflow sound from Acson Air Conditioner?
    • M
      Mary MorrisonAug 30, 2025
      The hissing airflow sound you hear from your Acson Air Conditioner during operation is due to liquid refrigerant flowing into the evaporator coil.

Summary

1. NOMENCLATURE

Indoor Unit Model Code

Explains the breakdown of the indoor unit model number.

Outdoor Unit Model Code

Details the structure of the outdoor unit model designation.

2. FEATURES

11. CONTROLLER

OPERATING STATE AND FAULT TABLE

Wired Remote Control Fault Codes

Lists error codes displayed on the wired remote for diagnostics.

PHASE SEQUENCER

13. SERVICING AND MAINTENANCE

14. TROUBLESHOOTING

General Troubleshooting Guide

Lists common issues like no restart, slow airflow, or odors with possible causes.

Detailed Fault Scenarios

Addresses condensation, water leakage, hissing sounds, and dim displays.

Compressor and Airflow Troubleshooting

Troubleshooting continuous compressor operation or lack of cool/hot air.

15. EXPLODED VIEW AND PARTS LIST

Acson A5CK15CR Specifications

General IconGeneral
RefrigerantR32
Outdoor Unit Noise Level52 dB(A)
TypeSplit Type
Cooling Capacity12000 BTU/hr
Power Supply220-240V, 50Hz
Operating Temperature (Cooling)18°C to 43°C