WATER SOURCE HEAT PUMP
WALL MOUNTED
SPLIT TYPE AIR CONDITIONER
(G Series)
WSHP
INSTALLATION MANUAL
Model: IM-5WMWSG-1204-ACSON
Part Number: R08019029753

Table of Contents

Questions and Answers

  • C
    Cynthia Jennings DDSAug 7, 2025
    What to do if my Acson A5LC20CR unit does not operate?
    • S
      Stacy WalkerAug 7, 2025
      If your Acson Air Conditioner unit doesn't operate, here are a few things to check: * Ensure there isn't a power failure or a blown fuse; if so, restore the power supply or replace the fuse. * Verify the power plug is securely connected. * Examine the delay timer settings to ensure they are correct. If the problem continues after checking these, please contact the air conditioner unit installer.
  • M
    Matthew TuckerAug 12, 2025
    Why is the air flow too low in my Acson Air Conditioner?
    • C
      Craig WattsAug 12, 2025
      If the airflow in your Acson Air Conditioner is too low, here's what might be happening and how to address it: * The air filter might be dirty. Try cleaning or replacing the air filter. * Open doors or windows can affect airflow. Make sure to close all doors and windows. * The air suction and discharge may be clogged. Unclog them to improve airflow. * The set temperature might be too low. Try increasing the regulated temperature.
  • J
    James YoungAug 17, 2025
    How to get rid of bad odor from Acson A5LC20CR Air Conditioner discharge air flow?
    • A
      Amanda FosterAug 17, 2025
      If the discharge airflow from your Acson Air Conditioner has a bad odor, it may be caused by substances like cigarette smoke, or perfume that have adhered to the coil. Clean the coil to remove these substances.
  • S
    Sherri WilsonAug 22, 2025
    What to do if water is flowing out from the Acson A5LC20CR unit?
    • S
      Susan HansenAug 22, 2025
      If water is flowing out from your Acson Air Conditioner unit, switch off the unit and call your dealer.
  • A
    Anthony SmithAug 27, 2025
    Why is there condensation on the front air grille of my Acson A5LC20CR indoor unit?
    • M
      Michelle GarrettAug 27, 2025
      Condensation on the front air grille of your Acson Air Conditioner's indoor unit can occur due to air humidity after a long period of operation, or if the set temperature is too low. Try increasing the temperature setting and operating the unit at high fan speed.
  • C
    Carolyn GuerraSep 1, 2025
    Why Acson A5LC20CR compressor does not operate immediately after the unit is started?
    • J
      Jason HarrisSep 1, 2025
      If the compressor in your Acson Air Conditioner does not operate immediately after starting the unit, wait for 3 to 4 minutes for it to start operating.

Summary

Installation Manual

Safety Precautions

General Safety Warnings and Cautions

Important safety guidelines and warnings for installation and operation.

Installation Diagram and Procedure

Indoor Unit Installation

Guidance on positioning and installing the indoor unit correctly.

Refrigerant Piping Specifications

Piping Length, Elevation, and Works

Guidelines for piping length, elevation limits, and connection work.

Electrical and Wiring Specifications

Electrical Wiring Connection Diagrams

R410 A Handling and System Charging

Special Precautions for R410 A

Important safety and handling guidelines specific to R410A refrigerant.

Vacuuming and Charging Procedures

Step-by-step guide for vacuuming the system and charging refrigerant.

Unit Operation Modes

Service and Maintenance

Troubleshooting and Long-Term Storage

Troubleshooting Common Faults

Identifies common faults and their potential causes and actions.

Acson A5LC20CR Specifications

General IconGeneral
BrandAcson
ModelA5LC20CR
CategoryAir Conditioner
LanguageEnglish