eayalaAug 4, 2025
How to turn on Acson Air Conditioner after power failure?
- RRobert HornAug 4, 2025
If your Acson Air Conditioner unit does not resume after a power failure, turn on the unit with the wireless or wired controller.
How to turn on Acson Air Conditioner after power failure?
If your Acson Air Conditioner unit does not resume after a power failure, turn on the unit with the wireless or wired controller.
What to do if there is condensation on the front air grille of my Acson A5CK50AR Air Conditioner?
If there's condensation on the front air grille of your Acson Air Conditioner's indoor unit, it's likely due to air humidity or a set temperature that's too low. Try increasing the temperature setting and operating the unit at a high fan speed to resolve this.
Why warm air does not come out of my Acson A5CK50AR on heating cycle?
If your Acson Air Conditioner is on a heating cycle and warm air isn't coming out, it's likely that the unit is in defrost mode. The heating operation will resume automatically after the defrost cycle ends.
What to do if Acson Air Conditioner compressor does not operate after starting?
The compressor in your Acson Air Conditioner is designed with a protection feature to prevent frequent starts. Please wait 3 to 4 minutes; the compressor should start operating on its own.
Why is the wireless controller display dim on my Acson A5CK50AR?
If the wireless controller display for your Acson Air Conditioner is dim, the batteries may be discharged or not correctly inserted, or the assembly might not be good. Check the batteries and their placement.
Why does my Acson A5CK50AR discharge airflow have a bad odor?
If the discharge airflow from your Acson Air Conditioner has a bad odor, it may be due to cigarettes, smoke particles, perfume, or other substances that have adhered to the coil. Contact your nearest dealer for assistance.
What causes hissing airflow sound from Acson A5CK50AR?
The hissing airflow sound you hear from your Acson Air Conditioner during operation is due to liquid refrigerant flowing into the evaporator coil.
Energy Efficiency Ratio (EER) | 11.2 BTU/hr/W |
---|---|
Refrigerant | R32 |
Indoor Unit Dimensions (W x H x D) | 970 x 300 x 224 mm |
Outdoor Unit Dimensions (W x H x D) | 800 x 553 x 325 mm |
Power Supply | 220-240V, 50Hz |
Details the breakdown and meaning of indoor unit model codes.
Details the breakdown and meaning of outdoor unit model codes.
Covers the microcomputer and wireless remote controllers for precise operation.
Explains settings for temperature, fan speed, operation modes, and timers.
Lists error codes shown on the 7-segment display of wired remotes.
Instructions for cleaning air filters and the indoor unit panel and grille.
Recommended checks for drain pan, fan, coils, power supply, and compressor.
Tasks to perform after a period of extended shutdown for optimal operation.
Lists common malfunctions and their possible causes and corrective actions.