AIRES SPLIT DUCTED UNIT
Outdoor
Installation and Commissioning Guide
CAUTION:
The system is charged with flammable
refrigerant, safety checks are necessary to
ensure that the risk of ignition is minimised.
IMPORTANT NOTE:
This unit is designed for use with R-32 refrigerant only.
Please read the R-32 Safety Manual and this manual carefully
before installing or operating your air conditioning unit.
Information in this manual is to be used in conjunction with
the R-32 Safety Manual.
Make sure to save this manual for future reference.
Model Numbers
Single Phase Three Phase
CRS10AS CRS13AT
CRS13AS CRS15AT
CRS15AS CRS17AT
CRS17AS

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ActronAir AIRES CRS17AT and is the answer not in the manual?

ActronAir AIRES CRS17AT Specifications

General IconGeneral
BrandActronAir
ModelAIRES CRS17AT
CategoryAir Conditioner
LanguageEnglish

Summary

Introduction

General Information

Safety Instructions

Hazardous Voltage - Risk of Electrocution

Warning about live electrical supply. Always turn off power from the main isolator before service.

Installation Information

Recover and Recycle Refrigerants

Instructions on refrigerant recovery, recycling, and reuse. Never release refrigerant to the atmosphere.

Outdoor Unit Preparation

Field Pipe Connection

Piping and Brazing

Instructions and precautions for piping and brazing the refrigeration lines.

Pressure Testing

Procedure for pressure testing the system to ensure integrity.

Electrical Installation

Wiring Diagram

Diagrams illustrating the electrical wiring connections for the air conditioning system.

Electrical Connection

Details on connecting the power supply and control wiring for split units.

Demand Response Management

Configuring and Commissioning Setup

Third Party Control Input (Indoor and/or Outdoor Board)

Indoor Fan Commissioning

Refrigerant Charging

REFRIGERANT CHARGE DETAILS (R-32)

Table detailing refrigerant charge amounts for different models.

Charging Method: Subcooling and Superheat

Procedure for adjusting refrigerant charge using subcooling and superheat.

Specifications for Refrigeration

Maintenance