SENC 150 Reading Head Replacement Instructions
9
Installing end cap(s)
Slide brackets against
reading head snap into place.
Insert brackets at 45°
and twist to lock in scale grove.
Installing alignment brackets
Attach the alignment brackets provided by inserting the top
ears into the bottom grooves in the scale case.
Numbers and letters on reading head casting and alignment
brackets correspond when assembled.
Determining cable direction
Determine cabel exit direction before mounting the encoder.
To change the cable exit direction, remove the cover plate
and rotate it 180°.
7 Preparing the remounting
K1 - cable exit right side
K2 - cable exit left side
T-10 torx screw
Do not pull out the PCB!
Do not clamp the wires!
T-10 torx screw
1
1
1
1
1
1
max. 70 Ncm!
spring clip