8
7 The button ”New hardware”
The button ”New hardware” in Edge Manager is used for ”releasing” a
configuration file. Meaning allowing for the configuration file to be used by
a new or a factory reset Edge RT7020.
7.1 Changing of PCB
Please note that if the PCB is exchanged on the unit a new activation of the
terminal towards the Connect platform, and the Alarm Receiving Centre,
must be performed. Therefore AddSecure and the ARC must be contacted.
• Check that the replacement product is of the same type and model as the
product it’s replacing. Make sure all connections and DIP-settings are done
in the same way on the new unit as on the old one. Finally power up the unit
and await the LEDs to indicate “Ready for programming”.
• Log onto Edge Manager and find the correct configuration file.
• Click ”New hardware”
• Click “Program” and enter the Activation Code printed on the label of the
new unit.
• Once the programming is completed, click “Commission”.
7.2 Factory reset of the Edge RT7020 Enterprise
To reset an already installed Edge RT7020 to factory default:
• Disconnect the power.
• Put DIP3 in the ON position.
• Connect the power.
• Wait until the blue LED starts to blink.
• IMPORTANT: Remember to reset the DIP3 to the OFF position (otherwise
the terminal will be factory reset again at the next power cycle)
• Log on to Edge Manager and chose the correct configuration.
• Click ”New hardware”
• Click “Program” and if needed enter the Activation Code.
• Once the programming is completed, click “Commission”.