5
SAFETY RELATING TO REFRIGERANT R290
Read these warnings carefully.
This appliance contains the refrigerant R290. R290 is a refrigerant that
complies with the relevant European Directives. Never perforate the
refrigerant circuit. R290 is ammable (GWP3)!
Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open ames, an operating gas appliance or an
operating electric heater).
Do not pierce or burn any of the components of the cooling circuit of the
unit. Do not set light to the unit.
The appliance shall be stored so as to prevent mechanical damage from
occurring.
Appliance should be installed, operated and stored in a room with a oor
area larger than 11m
2
.
Be aware that the refrigerants may not contain an odour, which means you
cannot smell leaks..
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
A warning that the appliance shall be stored in a well-ventilated area where
the room size corresponds to the room area as specied for operation.
Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certicate from an industry-accredited
assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment
specication.
Servicing shall only be performed on the grounds as recommended by the
equipment manufacturer. Maintenance and repair requiring the assistance
of other skilled personnel shall be carried out under the supervision of the
person competent in the use of ammable refrigerants.