ADEMCO N7227V5 User Manual

ADEMCO N7227V5
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
N7227V5 10/00
9
9
,
,
6
6
7
7
$
$
6
6
(
(
6HFXULW\6\VWHP
,QVWDOODWLRQDQG6HWXS*XLGH
*
ARMED
READY
PANIC
OFF AWAY STAY
MAX TEST BYPASS
INSTANT CODE CHIME
READY
1
2
3
654
897
0
*
#
ALARM
CHECK
FIRE
AWAY
STAY
INSTANT
BYPASS
NO AC
CHIME
BAT
NOT READY
®

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ADEMCO N7227V5 and is the answer not in the manual?

ADEMCO N7227V5 Specifications

General IconGeneral
BrandADEMCO
ModelN7227V5
CategorySecurity System
LanguageEnglish

Summary

SECTION 2 Installing the Control

Mounting the Cabinet

Details on physically installing the control unit to a sturdy wall in a suitable location.

Standard Phone Line Connections

Guidance on how to properly connect the system to the telephone network.

SECTION 3 Remote Keypads

Wiring to the Keypads

Instructions for connecting keypads to the control panel, including wire gauge.

SECTION 4 Basic Hardwired Zones 1–6

Installing the Hardwired Zones

General steps for installing basic hardwired zones and their characteristics.

Wiring Burglary and Panic Devices to Zones 1-6

Specific wiring instructions for burglary and panic devices connected to zones.

Wiring 4-Wire Smoke/Combustion Detectors on Zone 5

Detailed wiring procedures for 4-wire smoke and combustion detectors.

SECTION 5 Wireless Expansion (5800 System)

Installing the 5881/5882 Receiver

Steps for installing the RF receiver for wireless zone expansion.

Programming Wireless Zones

Procedures for programming wireless transmitters into the system.

SECTION 6 Relay Output Devices

Programming Options

Defines how to program relay actions, start, and stop conditions.

SECTION 7 4285 and 4286 VIP Module

Installing the VIP Module

Steps for installing the Voice Interactive Phone (VIP) Module.

VIP Module Wiring

Instructions for wiring the VIP Module to the control panel and phone line.

SECTION 8 External Sounders

Sounder Connections and Power

Details on wiring external sounders to alarm output terminals.

SECTION 10 Audio Alarm Verification (AAV) Unit

Wiring Connections

Diagrams illustrating how to connect the AAV unit with a 4204 Relay Module.

SECTION 11 Final Power-Up

Earth Ground Connections

Importance and methods for establishing a proper earth ground connection.

Wiring the AC Transformer

Instructions for wiring the 1321 transformer to the control board.

AC Power-Up

Steps to power on the system and initial keypad displays.

Calculating the Battery Size Needed

Procedure to determine the correct backup battery size based on current draw.

Connecting the Backup Battery

Steps for making the physical connections for the backup battery.

SECTION 12 Mechanics of Programming

SECTION 13 Zone Response Type Definitions

SECTION 14 Data Field Descriptions

Descriptions of System Data Fields

Detailed explanations of all system data fields for programming.

SECTION 15 Zone Programming (+56/*58 Menu Mode)

SECTION 16 Output Device Programming (+80 Menu Mode)

SECTION 20 System Communication

SECTION 21 System Operation

SECTION 22 Testing the System

Test Procedures

General steps for thoroughly testing the installed alarm system.

APPENDIX B Limitations and Warranties

THE LIMITATIONS OF THIS ALARM SYSTEM

Important warnings about system limitations, potential failures, and user responsibilities.