Data Labels Found on Appliance:
820
TESTED BY:
AUSTRALIAN SOLID FUEL TESTING
3 GARDEN ST, MORWELL,
VIC 3840 AUSTRALIA
Unit
TEST REPORT NO:
ASFT17109
DATED: 11/2017
WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012:2014 & AS/NZS 4013:2014
Burning Hardwood
Maximum Avearge Heat Output
kW
9.7
Overall Average Efficiency
%
63
Particulate Emission Factor
g/kg
0.8
Maximum firewood load
kg
9.7
Minimum clearance distances from combustible materials
mm
See Page 10/15.
Flue Diameter
mm
200
Imported By:
Castworks,
57 Industrial Drive,
Braeside, Vic 3195
Manufactured by:
A.D.F. Lda.
Z.I. Relvinha, Sarzedo A.P. 55
3304-909 Arganil-Portugal
1000
TESTED BY:
AUSTRALIAN SOLID FUEL TESTING
3 GARDEN ST, MORWELL,
VIC 3840 AUSTRALIA
Unit
TEST REPORT NO:
ASFT17106
DATED: 11/2017
WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012:2014 & AS/NZS 4013:2014
Burning Hardwood
Maximum Avearge Heat Output
kW
12.5
Overall Average Efficiency
%
64
Particulate Emission Factor
g/kg
1.2
Maximum firewood load
kg
13.7
Minimum clearance distances from combustible materials
mm
See Page 10/15.
Flue Diameter
mm
200
Imported By:
Castworks,
57 Industrial Drive,
Braeside, Vic 3195
Manufactured by:
A.D.F. Lda.
Z.I. Relvinha, Sarzedo A.P. 55
3304-909 Arganil-Portugal