PHYSICAL DATA
Model
18 24 30 31 36 42
Available Voltages 208/240 V, 60 Hz, 1 Phase
Maximum Elec. Heat available (kW) 10 10 10 10 15 15
Transformer Size and Type 40VA, Class 2
Blower Data
Wheel (dia.” X width”) 10 x 6 10 x 6 10 x 6 10 X 8 10 x 8 10 x 8
Motor H.P. 1/5 ¼ 1/3 1/3 ½ ½
F.L.A.@240 V 1.1 1.9 2.2 2.6 3.0 3.0
Speed 3 3 3 3 3 3
Nominal CFM 600 800 1000 1000 1200 1400
Air Filter Size 20” x 20” 20” x 20” 20” x 20” 20” x 25” 20” x 25” 20” x 25”
Refrigerant Conn.(IDS)Suction ¾” ¾” ¾” ¾” ¾” 7/8”
Refrigerant Conn. (IDS) Liquid 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Florator Piston Size 53 59 67 67 73 80
Weights Approx. lbs. 99 101 103 118 118 121
AIR HANDLER MAINTENANCE
AT THE BEGINNING OF EACH HEATING SEASON THE UNIT SHOULD BE SERVICED BY A QUALIFIED INSTALLER OR SERVICING AGENCY.
ASSISTANCE OR SERVICE
IF YOU NEED FURTHER ASSISTANCE, YOU MAY CONTACT US AT THE ADDRESS BELOW OR E-MAIL US WITH ANY QUESTIONS OR CONCERNS. PLEASE
INCLUDE A DAYTIME PHONE NUMBER IN YOUR CORRESPONDENCE
.
A
DVANCED DISTRIBUTOR PRODUCTS
1995
AIR INDUSTRIAL PARK ROAD
G
RENADA, MS 38901
E-
MAIL: ADP.FEEDBACK@ADPNOW.COM