ADS EOS - Electromagnetic Immunity Standards; Immunity Test Conformance

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADS
EOS
Extraoral
Suction
System
,
Instructions
For
Use
and
installation
ADS
Dental
Syslom
Statement
of
Manufacturer
-
Electromagnetic
Immunity
Extraoral
Suction
System
is
designed
for
electromagnetic
environment
described
below
.
Be
sure
to
apply
.
Electromagnetic
Immunity
Test
IEC6061
Test
Level
Test
Level
Conformance
Electromagnetic
Environment
3V
(
Effective
Value
)
3V
/
m
The
isolation
distance
between
portable
and
mobile
RF
communications
devices
and
any
part
of
the
Extraoral
Dentistry
Suction
System
,
including
cables
,
should
not
be
less
than
recommended
isolation
distance
,
The
recommended
isolation
distance
is
calculated
by
a
formula
corresponding
to
the
frequency
ofthe
transmitter
.
Recommended
isolation
distance
formula
:
Radiofrequency
Conduction
GB
/
T
3V
(
Effective
Value
)
150kHz
--
80MHz
dzl2
/
7
dz1.2
/
80
MHZ
800
MHZ
17626.2
Radio
d
=
1
.
2
800
MHz
--
2.5
GHz
3V
/
m8OMHz5GHz
Frequency
Radiation
GB
/
T
17626.3
P
-
based
on
the
transmitter's
maximum
rated
output
power
provided
by
transmittermanufacturer
,
in
watts
(
W
)
;
d
-
Recommended
isolation
distance
,
in
meters
(
m
)
The
field
strength
of
the
fixed
RF
transmitter
is
determined
by
surveying
the
electromagnetic
field
a
,
and
in
each
frequency
range
dshould
be
lower
than
the
compliance
level
.
interference
may
occur
near
the
equipment
marked
with
the
following
symbol
.
Note
1
:
At
SOMHz
and
800MHz
frequencies
,
apply
higher
frequency
band
formula
.
Note
2
:
These
guidelines
may
not
be
suitable
for
all
situations
.
Electromagnetic
propagation
is
affected
by
absorption
and
reflection
from
buildings
,
objects
and
human
bodies
.
The
field
strengths
of
fixed
transmitters
,
such
as
:
base
stations
for
wireless
(
cellular
/
cordless
)
phones
and
terrestrial
mobile
radios
,
amateur
radios
,
AM
and
FM
radio
broadcasts
,
and
television
broadcasts
,
cannot
be
accurately
predicted
theoretically
.
To
assess
the
electromagnetic
environment
of
fixed
RF
transmitters
,
surveys
of
electromagnetic
sites
should
be
considered
.
If
the
measured
field
strength
of
the
Extraoral
Suction
System
is
higher
than
the
applicable
RF
compliance
level
above
,
the
Extraoral
Suction
System
should
be
observed
to
verify
that
it
can
operate
normally
.
If
abnormal
performance
is
observed
,
supplementary
measures
may
be
necessary
,
such
as
reorienting
or
repositioning
the
Extraoral
Suction
System
.
In
the
entire
frequency
range
of
150kHz
to
80MHz
,
the
field
strength
should
be
lower
than
3V
/
m
.
25