descrambling. 0 is default.
LNB State - This configuration will enable or disable power on the input connector to power
the LNB. If on, the user can select the voltage and tone placed on the connector via the
Polarity and Tone configurations.
LNB Polarity - This control is primarily used in “Universal” LNB applications. The LNB
Polarity control allows for LNB polarization selection; the 13VDC source will select the
Vertical polarity and the 18VDC source will select the horizontal polarity. For typical “C” and
“Ku” band applications, the 18 VDC option is recommended.
Tone - This control is used only for Universal LNB applications. A universal LNB can route
the high or low band from either polarity to the IRD. The high band is selected by enabling
the 22 kHz tone and the low band is selected when the 0 Hz tone is enabled.
IP Params
IP Params allow a user to configure IP Receive parameters and see detailed IP statistics.