CM1-SERIES
pVtyp selected (lNspd),the fun.
will display
Eunit(Engineer Unit):
Line speed display unit selection
m/mn: (M/min)
cm/mn: (CM/min)
yd/mn: (Yd/min)
ft/mn: (Ft/min)
pVtyp selected (lNspd) ,the fun.
will display
diamt(Diemeter):
Shaft diameter set
pVdp:Decimal Point of PV;
There are two definitions for
thissetting:
1. If fun. setting is auto,the pVdp set
point for the relay output of decimal
places set;
2. If fun. setting is semior manul,the
pVdp set point for the relay output &
PV of decimal places set;
Setting Range:
0 / )0 /
)00 / )000 / 0.0000
factr(Factor): Display scale factor;
Display value = calculated value x scale
factor
Setting Range: 0.001~9.999
lOcut (Low Cut): Low Cut the PV
[lOcut]is setting 0.50,when PV between
-0.50~+0.50,Display is “0”。
Setting Range:
-19999~+29999 counts
[lOcut]is setting -0.10,PVLess
than equal to (< = -0.10),Display is
“-0.10”。
itOmd:Input Time Out Mode
When the frequency is too low,
this table shows the calculation based
on this function to set the time zero value。
auto(Auto): Automatic calculation
zero display timo。
manul(Manual): Manually calculation
zero display timo。
itOmd selected manul,the Fun.
desplay
ito(Input Time Out): Zero time
setting
。
When the frequency is too low to
display zero value(TIME OUT) time setting
Setting Range: 0.0 sec~999.9sec