CM1-SERIES
28 / 28
Rev 1.3
2018-07-02
CM1-RL/CM1-F
User Level
Name
Address
Range
Explain
Initial
Write/Read
Note
PV
0000h
0~99999
Present Value (*High word)
R
0001h
Present Value (*Low word)
min
0002h
0~99999
The Minimum of PV (*High word)
0
R
0003h
The Minimum of PV (*Low word)
max
0004h
0~99999
The Maximum of PV (*High word)
0
R
0005h
The Maximum of PV (*Low word)
Engineer Level
Input Group
Name
Address
Range
Explain
Initial
Write/Read
Note
pv.typ
0006H
0~4
Choose display type: wire-speed / speed /
frequency 0: Linear Speed 1: RPM 2:RPS3:
HZ 4KHZ
0
R/W
ppr
0007h
1~99999
Input Pulse
1
R/W
0008h
e.unit
0009h
0~3
Straight line speed display unitselection
0: M/min 1: CM/min 2:Yard/min 3: Feet/min
0
R/W
diamt
000Ah
0.1000~9.9999(M)
Shaft diameter
1000
R/W
000Bh
dp
000Ch
0~4
Decimal point
0:00000 1:0000.0 2:000.00 3:00.000
4:0.0000
0
R/W
factr
000Dh
0.0001~9.999
Display factor
1000
R/W
lOcut
000Eh
-19999~19999
Low Cut
0
R/W
itOmd
00Fh
0~1
Input signal time out model
0: Auto 1: Manual
0
R/W
ito
0010h
1~9999(x0.1Sec)
time out setting
10
R/W
avg
0011h
1~99
Average
1
R/W
Dfilt
0012h
1~99
Digital filtering
5
R/W
Pcode
0013h
0000~9999
Pass Code
1000
R/W
RS485 Group)
Name
Address
Range
Explain
Initial
Write/Read
Note
adres
0014h
1~255
RS485 Station Address No.
1
R/W
baud
0015h
0~5
RS485 Communication rate
0:1200 1:2400 2:4800 3:9600
4:19200 5:38400
3
R/W
prity
0016h
0~3
RS485 Parity
0:n-8-1 1:n-8-2 2:odd-8-1
3:even-8-1
1
R/W
INIT Group
Name
Address
Range
Explain
Initial
Write/Read
Note
init
0017h
0000~9999
Initialization (code:7170)
0000
R/W