55 ICAM-500 Programming Guide
Chapter 4 CamNavi2 SDK API Manual
4.8.2.2 class DigitalOutput
class digitalio.DigitalOutput(board, dev_name)
property user_output
User set output level. This property works on op_mode is 0
Getter: Read output signal level.
Setter: Set output signal level.
Value: 0: low level
1: high level
Raises: ValueError
Input value out of range.
property op_mode
DO signal generate mode
Getter: Read DO op mode.
Setter: Set DO op mode.
Value: 0: User output DO
1: DI bypass(diabled)
Raises: ValueError
Input value out of range.
property delay_time
DO signal delay output.
Getter: Read delay time.
Setter: SSet DO delay time.
Value: range: [0..65535]
unit: Milli second.
Type: int
Raises: ValueError
Input value out of range.