Loading...
Find the video tutorial "How to install your
AEG Extractor Hob 80 cm" by typing out the
full name indicated in the graphic below.
www.youtube.com/electrolux
www.youtube.com/aeg
How to install your AEG
Extractor Hob 80 cm
Filter housing assembly
Before first use make sure to insert the filter
inside the housing, with the black sides facing
inwards and the silver sides facing out. Refer
to "Cleaning the hood filter". Once the filter
housing is assembled, put it inside the hood
cavity and place the grid on the hood.
3.5 Connection cable
The hob is supplied with a connection
cable.
To replace the damaged mains cable, use
the cable type: H05BB-F or H03V2V2-F
which withstands a temperature of 90 °C
or higher. The single wire must have a
diameter of minimum 1,5 mm². Speak to
your local Service Centre. The connection
cable may only be replaced by a qualified
electrician.
WARNING!
All electrical connections must be made
by a qualified electrician.
CAUTION!
Connections via contact plugs are
forbidden.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
CAUTION!
Do not connect the cable without cable
end sleeve.
One-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Merge the black and brown cable ends.
4. Apply a new wire end sleeve on the
common cable end (special tool
required).
Cable cross section 2x1,5 mm²
N
L1
N
L
220-240 V~ 400V 2~N
L2
ENGLISH 9