45
When you have finished
• Nowyoucanstartironing.Alwaysturnthetemperature
control to “MIN” after use and remove the mains plug
(the control lamp in the handle goes off).
• Removethemainsplugfromthesocket.Thetankillumi-
nation goes out.
• Emptythewatertank.
• Allowthedevicetocooldownbeforeyouputitaway.
Anti-scale filter
Your steam iron station is fitted with an anti-scale filter. The
anti-scale filter cartridge becomes spent after filtering ap-
proximately 18 litres of water, depending on the hardness
of your water. It then loses its effectiveness and must be
replaced.
• Turnofftheappliance.
• Disconnectthemainsplugfromthemains.
• Removethewatertank.
• Removetheanti-scaleltercartridge.
• Fillthetankuptothemaximummark.Donotoverll!
• Insertanewanti-scaleltercartridge.
• Beforeturningontheappliance,waitafewminutesuntil
the new filter cartridge is saturated with water.
NOTE:
If you do not have a new anti-scale filter cartridge, you can
still iron with the used cartridge and distilled water.
Cleaning
WARNING:
• Alwaysremovethemainsleadbeforecleaning!
• Waituntilthemachinehascooleddowncompletely.
• Undernocircumstancesshouldyouimmersethe
device in water for cleaning purposes. Otherwise this
might result in an electric shock or fire.
CAUTION:
• Donotuseawirebrushoranyabrasiveitems.
• Donotuseanyacidicorabrasivedetergents.
• Children shall not perform cleaning without supervision.
• Cleanthecasingwithaslightlydampcloth.
• Cleanthesoleplateandtherestwithaslightlydamp
cloth.
• Anyresidualwatercanremaininthewatertank,but
should be poured out if it has been in the tank for a
prolonged period.
Troubleshooting
Fault Possible Cause Remedy
Device does not
work
Faulty mains
socket
Try another
socket
The thermostat
is set to the posi-
tion "MIN"
Set it to the de-
sired position.
Loud noises
during steam
operation
The tank is
empty
Check the tank
The device
suddenly stops
working during
operation
Is the electric cir-
cuit overloaded?
Check the house
fuse
The tank illumi-
nation does not
light after heat-
ing and no steam
is generated
The lime filter
cartridge is mis-
sion or has not
been set cor-
rectly.
Check the posi-
tion of the lime
filter cartridge.
The water tank
has not been in-
stalled correctly.
A "click"
confirms that
the water tank
has been set
correctly.
Technical Data
Model: ................................................................................ DBS 5573
Power supply: .......................................................230V~,50/60Hz
Power consumption:............................................................ 2200 W
Protection class: .................................................................................I
Maximum filling quantity of the water tank: ...................1.0 Litre
Net weight: ..............................................................approx. 3.25 kg
Subject to technical changes without prior notice!