12
For the Professional
2. Installation instructions
2.1 Composition of the unit
1 Terminal strip
2 Safety temperature limiter with reset button
3 Rear panel
4 Cold-water connection G 1/2"
5 Hot-water connection G 1/2"
6 Unit cover
7 Heating system
8 Electronics for power control
9 Cable entry for electric supply connection with rubber grommet
2.2 Important note
All the information in these Installation and Operating Instructions must be followed carefully.
These Instructions provide important details regarding safety, operation, installation, and
maintenance of the unit.
2.3 Technical data
Type MP 6 MP 8
Design Unvented
Rated overpressure MPa 1.0
Capacity l 0.5
Weight kg 2.4 2.4
Protection class as per VDE 1
Protection mode as per VDE IP 24
Test mark See unit rating plate
Water connection
1)
G 1/2 G 1/2
Electrical connection 1/N/PE ~ 220 V
Rated power at 220 V kW 6.0 8.0
Over-sink installation for ●●
supplying one or two draw-off points
Switch-on volumes 2.6 3.0
Switch-on flow pressure
Pressure loss MPa 0.025 0.03
Suitable for cold water l/min 2.6 3.0
1)
External thread
Suitable
Table 2