RevC 07/15/13 Page 31
LamdaAfterStartTrim is a 2-axis table that is used to modify the Lambda (AFR) for
specified time after starting the engine. This table adds a lambda offset for a small
period of time after the engine is started. By allowing a slightly richer mixture target, it
will keep the engine from stalling or running rough immediately after starting and the
lambda correction to a minimum. The last column should be populated with “0” trim at
operating temperatures to prevent a continuous lambda offset.