Overview

The AEOLUS UC-1803 ICU.INCUBATOR is a professional veterinary equipment designed for the therapeutic and incubation needs of young pets. It is a newly developed pet ICU and young pet incubator that aims to fill a gap in the domestic pet care industry. Its compact structural design and moderate size make it suitable for most veterinary practices and pet hospitals.

Function Description:

The UC-1803 ICU.INCUBATOR provides a comprehensive range of functions to create an optimal environment for pet recovery and health improvement. Its core mechanism utilizes "dual duct and double circulation convective thermal regulation" to establish a bacteria-free therapeutic and incubation environment.

Key functions include:

  • Accurate Temperature Control: The device employs dual duct and double circulation convection heating technology for rapid and even temperature rise, minimizing temperature shock. It also features a special pet medical refrigerator matching system for fast and effective cooling (optional). The PID control technology ensures precise and energy-efficient temperature regulation, addressing inertia temperature errors.
  • Accurate Humidity Control: High-frequency oscillation technology is used to produce mist without heating, saving up to 90% of energy compared to heating atomization. It releases large amounts of negative ions during atomization, which react with smoke and dust in the air, causing precipitation and improving air quality. The humidifier water tank has a built-in design for easier cleaning and is equipped with an automatic water cut-off protection function for safety.
  • Negative-ion Generation: The incubator generates a high concentration of negative ions, often referred to as "air vitamins," which are crucial for animal health. This feature aims to improve immunity, antibacterial ability, and natural healing, contributing to the overall well-being of pets and aiding in the treatment of various diseases. The device meets medical-level negative-ion emission standards.
  • Sterilization Function: A UVC ultraviolet sterilizer is integrated, utilizing 253.7nm UV-C rays for germicidal effect. This physical disinfection method is highly efficient, has no secondary pollution, and is easy to manage and automate. It boasts strong radiation intensity, high stability, and high transmittance to quartz glass, achieving a sterilization rate of 99%-99.9% in one to two seconds against bacteria and viruses. The design includes a high brightness mirror sterilization reaction chamber to enhance effectiveness.
  • Medical Atomization Treatment Function: The UC-1803 is equipped with an external silent medical atomizer. It produces fine atomized particles (0.5-4 microns) of medicine, allowing for deep penetration into the respiratory system, including the finest bronchus and alveoli, for effective and painless treatment. The atomization volume is intelligently controlled, with a maximum volume of 0.5ml/min, ensuring even distribution and high medicine utilization. The atomizer operates at low noise levels, complying with pet ICU noise standards.
  • Carbon Dioxide Concentration Monitoring Systems: A precise carbon dioxide concentration monitor tracks CO2 levels within the ICU. If the concentration exceeds the set value and remains high, an alarm is triggered, and the intelligent ventilation system activates, bringing in outside air to improve air quality. This acts as a critical life defense line for pets, preventing conditions like pulmonary edema, cerebral edema, and hypoxia caused by high CO2 levels.
  • ICU Illumination Function: Ten-level LED lights adjustment allows for simulating various natural scenes (parent, forest oxygen bar, warm home, forest dawn and dusk twilight), providing a cozy and comfortable therapeutic environment for pets.
  • Security Mechanism: An intelligent alarm system is integrated, featuring fault display functions for extreme temperature, excessive moisture, lack-of-water, and main component faults. The intelligent switch power keys divide controls into power-on, start, and power-off modes, enhancing energy saving and safety.
  • Human-Oriented Structural Design: The integrated design of all equipment components within a control frame, separate from the control circuit, facilitates easy disassembly for cleaning, troubleshooting, and maintenance. It includes two medical device import interface channels for connecting external equipment like oxygen machines and a side access port with medical valve importing design for convenient pet injection and infusion.

Important Technical Specifications:

  • Power Supply Voltage: 220V ± 10% / 50Hz ± 2%
  • Input Power: ≤400VA
  • Ambient Temperature: 10°C ~ 35°C
  • Temperature Control Range (Cabinet): 15°C ~ 38°C (up to 39°C by special operations)
  • Temperature Fluctuation: ≤0.8°C
  • Average Temperature of Monitoring Chamber: ≤1.0°C
  • Cabinet Temperature Control Accuracy: ≤ ± 0.5°C
  • Temperature Rise Time: 5min ~ 20min
  • Noises in Monitoring Room: ≤30dB
  • Whole Machine Earth Leakage Current: ≤0.5 mA (normal state), ≤1 mA (single fault state)
  • Withstand Voltage: 1500V/50Hz, lasted one minute without breakdown and flashover.
  • Operating Conditions (Ambient): Temperature 18°C ~ 30°C, Relative Humidity 40% ~ 65%
  • Transportation and Storage Conditions (Ambient): Temperature -10°C ~ 40°C, Relative Humidity ≤95%
  • Storage Temperature: -20°C ~ +70°C
  • Humidity Resistance: No abnormalities after 72 hours at +25°C and 95% RH without electricity.
  • High-temperature Characteristics: No abnormalities after 72 hours at +70°C without electricity.
  • Low-temperature Characteristics: No abnormalities after 72 hours at -20°C without electricity.
  • Drop Test: Functions properly after a 100cm (39.37") free fall onto a board.
  • Negative Ion Generator:
    • Input Voltage/Frequency: DC12V
    • Output Voltage: At DC12V -0.5--4.5KVd.c. (-3.5KV DC ± 0.5KV DC)
    • Anion Concentration: At DC12V ≥6×10⁶ PCS/cm³ ±10%
    • Insulation Resistance: Power line external box ≥20M Ω (500V DC)
    • Dielectric Strength: Power line external box AC 1800V 60HZ 5mA 3S No breakdown
  • Atomizer Droplet Size & Settlement Site:
    • 1-5μm: Dendritic Bronchus, Fine Bronchus, Alveolus
    • 5-20μm: Bronchus
    • 20-40μm: Upper Respiratory Tract (Nose, Throat, etc.)
  • Maximum Load Capacity of Machine Housing: 1-2 kilograms (2.2 to 4.45lbs).
  • Water Purification Filter Material Validity: 10-12 months (Phosphorus-silicon crystal, colorless, tasteless, non-toxic, meets National Sanitary Standard for Drinking Water GB1499-1988).

Usage Features:

  • Pre-heating: After turning on, preset the temperature and warm up for 3-5 minutes before use.
  • Water for Humidifier: Use distilled or purified water only. Do not fill the bottle with tap water.
  • Nebulizer Operation:
    • Install the external nebulizer on the left side, plug it into the ICU socket, and insert the nozzle into the port.
    • Fill the nebulizer cup with medicine liquid.
    • Turn on the nebulizer switch and then press the "Nebulize" button on the ICU control panel.
    • Two treatment timings: default 10 minutes, adjustable to 20 minutes by pressing the "-" button, and back to 10 minutes with "+".
    • Pressing "Nebulize" again during operation switches the nebulizer off.
    • Nebulization duration should not exceed 20 minutes to prevent pulmonary edema or water poisoning.
    • During nebulization, humidity and temperature control are turned off, and ventilation fans are off to ensure good nebulizing effects. The humidity alarm will reset 3 minutes after nebulization ends.
    • Sterilize the nebulizer, ambient air, and related equipment, and disinfect the animal's mouth, nose, and throat to prevent superinfection.
  • Anion Control: Press the "Anion" key to toggle ON/OFF. The indicator lamp shows the status.
  • Disinfection and Sterilization:
    • Ensure no pet is in the ICU and the door is closed before starting.
    • Press "SET" key + "Sterilization" key to enter disinfection mode.
    • All other functions are void in this mode except "SET" and "Sterilization" keys.
    • The UV disinfection lamp turns on, and left/right fans operate for ventilation.
    • Press "SET" key + "Sterilization" key again to exit disinfection mode.
    • Cannot be activated individually in normal work mode.
  • Illumination Intensity Control: Use the "+/-" keys to adjust ten grades of illumination intensity (highest is grade nine, lowest is closed). Default is closed at start-up.
  • CO2 Concentration Control: Press "SET" key for five seconds to enter parameter setting. The CO2 concentration alarm set point (default 800PPM) can be adjusted from 500PPM to 1200PPM using the humidity "+/-" keys.
  • Alarm Removal: Press "SET" key to disengage alarms.
  • Ventilation: Ensure proper ventilation; do not block air outlet and return air inlet.
  • Power Down: If not in use, turn the switch to OFF and allow for sufficient power down before turning it back on.

Maintenance Features:

  • Cleaning:
    • The ICU must be empty during cleaning.
    • Humidifier Cleaning: If the humidifier fails or spills water, remove the Water Level Sensors and Humidifier from the Water Vessel. Empty the vessel and brush off mineral substances (water scale, verdigris). Replace the humidifier filter if it fails.
    • Complete Cleaning: Periodically remove and clean parts and assemblies.
    • Disassembly Steps:
      • Remove four screws from the master control rack (right and left) to take it down.
      • Remove power connection plugs from power cords (note different colors for each component).
      • Allow control racks and electrical components to cool down for 30 minutes after shutdown before removal, as heaters reach high temperatures.
      • Remove four screws from the fan box and take out the heater. Clean the fan, avoiding removal of heat sinks, especially PTC heater bands.
      • Remove and clean filters behind the square plastic section inside the chamber.
      • Remove the humidifier for cleaning and maintenance if it is damaged or not working after separate cleaning.
    • Do not use alcohol or other organic solvents to wipe the thermostat cover; keep it moisture-free.
  • Maintenance Schedule: It is suggested to maintain the machine every two months during normal operation, following the removal, installation, and maintenance procedures.
  • Warranty:
    • One-year warranty for the whole machine.
    • Two-year warranty for key components (medical atomizer, humidifier, anion generator, ultrasonic sterilizer, fan, tank, door, master control panel, PTC heating chip).
    • Six-month warranty (from date of purchase) for replacement of key integral parts (medical atomizer, humidifier).
    • Paid repair services are available for the lifetime of the equipment under specific conditions (e.g., no warranty card, altered certificate, damage from misuse, unauthorized repair, or beyond warranty period).
    • Advance replacement warranty service is available for defective hardware after diagnosis, with replacement parts sent directly to the user, who must return the defective part within a specified period (normally five days). Transportation and insurance fees for returning defective parts are the user's responsibility.