1. Please read the Instruction Manual carefully before using the machine. Nurses (and other pet care
workers) should be trained to operate the machine under the guidance of qualified medical care
personnel who are familiar with the functions of ICU/Young Pet Incubator and understand the risks and
advantages of the machine.
2. Please count the parts and spare parts when unpacking, and read the Instruction Manual carefully.
3. The equipment shall be placed in a clean place with limited changes in temperature and humidity,
protected from direct sunlight and away from heat radiation.
4. To ensure the proper operation of the Pet ICU, please DO NOT fill the bottle with distilled water or
purified water.
5. After the machine is turned on, please preset the temperature value, and warm it up for 3-5 minutes
before use.
6. Please do not load weight onto the machine, and the maximum load capacity of the machine
housing is 1-2 kilograms (2.2 to 4.45lbs).
7. Unsanitary cleaning materials will cause the generation of carbon dioxide, and thus increase the
carbon dioxide concentration in the pet ICU. The equipment should be inspected and cleaned. And the
air purifying materials shall be replaced in a timely manner and on a regular schedule.
8. The machine is equipped with an intelligent alarm system sensor for five faults; extreme tempera-
ture, excessive moisture, indoor carbon dioxide concentration, lack-of-water in the tank and power
supply Interruption. This alarm system is tested and proven to be safe and reliable. If the machine fails,
please inspect the systems immediately to find out reasons and eliminate the faults. If the faults cannot
be eliminated in a short time, please stop medical treatment or care for pets, and ask for professionals
or personnel from the AEOLUS Company to repair the machine.
9. Allow for the machine to have proper ventilation. Do not block the air outlet and return air inlet.
10. After being powered on, if the machine is not used, in order to ensure safety and energy-saving,
please turn the switch to off position and allow for sufficient power down before turning the switch back
to on position.
11. Do not use alcohol or other organic solvents to wipe the thermostat cover of the tank. Keep it
moisture free.
1. Provides bacteria free and thermostatic incubation cocoon for young pets.
2. Allows for body temperature recovery, fluid infusion, atomization treatment, incubation, health
improving and comfortable, stable stay in the hospital (for observation for sick, dying and weak pets).
Built-in humidifier bottle: some parts of medical atomizer and the tank are separately packed. Please
pay attention not to damage or miss any parts or spare parts when unpacking.
AEOLUS UC-1803 ICU.INCUBATOR cabinet
Medical atomizer
Power line of AEOLUS UC-1803 ICU.INCUBATOR
Waste tray of AEOLUS UC-1803ICU.INCUBATOR
Water purification filter material (Phosphorus-silicon crystal)
User Manual
The external Nebulizer can be installed on the left
side of KANIKARE UC-1803 ICU.INCUBATOR.
Insert the power plug into the socket on ICU;
insert the nozzle of Nebulizer into the port on the
left side as showed in Figure 9.1.1.
Before nebulization, switch on the nebulizer by
pressing the switch on the nebulizer and then turn
to the operation panel of ICU.
As shown in Figure 4.2.1, the Humidifier Vessel is installed in the right control chamber of the AEOLUS
UC-1803 ICU.INCUBATOR. As shown in Figure 4.2.2, open the outlet cover, take out the built-in Water
Vessel, fill the built-in Water Vessel with water, as shown In Figure 4.2.2. And then put back the vessel
and place the cover in the proper position.
Notes:
a) The Humidifier and Water Level Sensor should be placed securely onto the vessel to prevent the
spill of water.
b) The water level should not be above the Highest Level Line (HLV).
c) The purpose of the water purification filter material is to remove hard water scale and improve the
water quality. The validity period of each placement is 10-12 months. Colorless, tasteless and non-tox-
ic, the filter material meets the National Sanitary Standard for Drinking Water& GB1499- 1988 and can
effectively improve water quality.
2. Installation of Humidifier Vessel
Outlet Cover
Sensor
of Vessel
Water Vessel
Figure 4.2.1 Figure 4.2.2
Figure 9.1.1