Setting Description
0 - 99 The brightness level
256 - 316 The minute value of ON time
65536 - 65560 The hour value of ON time
16777215 - 16777222 The day value (Mon to Sun)
Parameter 86: Set appointment 2
Set the ON time of output load.
Size: 4 Byte, Default Value: 2293760
Setting Description
0 - 99 The brightness level
256 - 316 The minute value of ON time
65536 - 65560 The hour value of ON time
16777215 - 16777222 The day value (Mon to Sun)
Parameter 90: Enables/disables parameter 91 and 92 below:
Enables/disables the function of parameter 91 and 92.
Size: 1 Byte, Default Value: 0
Setting Description
0 Disable
1 Enable
Parameter 91: Set the threshold value of wattage.
Threshold change in wattage (in terms of wattage) to induce an automatic report.
Size: 2 Byte, Default Value: 25
Setting Description
0 - 60000 The thershold value range is 0 to 60000
Parameter 92: Set the threshold value of wattage.
Threshold change in wattage (in terms of percentage) to induce an automatic report.
Size: 1 Byte, Default Value: 5
Setting Description
0 - 100 The thershold value range is 0 to 100
Parameter 100: Set parameter 101-103 to default value.
Set parameter 101-103 to default value.
Size: 1 Byte, Default Value: 0
Setting Description
0 Reset the parameter 101-103
Parameter 101: To set which reports need to be sent in Report group 1.
To set which reports need to be sent in Report group 1.
Size: 4 Byte, Default Value: 0
Setting Description
1 Send Meter Report of voltage (V)
2 Send Meter Report of current (A)
4 Send Meter Report of wattage (W)
8 Send Meter Report of energy (kWh)
Parameter 102: To set which reports need to be sent in Report group 2.
To set which reports need to be sent in Report group 2.
Size: 1 Byte, Default Value: 0