Setting Description
0 Unknown load.
1 Resistive load
2 Capacitive load
3 Inductive load
Parameter 131: Set the min brightness level that the load can reach to.
Set the min brightness level that the load can reach to.
Size: 1 Byte, Default Value: 0
Setting Description
0 - 99 The level range is 0 to 99.
Parameter 132: Set the max brightness level that the load can reach to. Note:
Set the max brightness level that the load can reach to.Note:
Size: 1 Byte, Default Value: 99
Setting Description
0 - 99 The level range is 0 to 99.
Parameter 249: Set the recognition way of load
Set the recognition way of load
Size: 1 Byte, Default Value: 2
Setting Description
0 Never recognize the load when power on
1 Only recognize once when first power on
2 Recognize the load once power on
Parameter 252: Lock/unlock configuration parameters
Lock/unlock configuration parameters.
Size: 1 Byte, Default Value: 0
Setting Description
0 Unlock
1 Lock
Parameter 255: Reset the Nano Dimmer
Reset the Nano Dimmer to factory default.
Size: 4 Byte, Default Value: 0
Setting Description
0 Reset all configuration parameters to factory default setting
1431655765 Reset to factory default setting and removed from the z-wave network
Technical Data