1
The alarm will be triggered
by closed state, and be
disabled by open state.
256 Smoke alarm.
512 CO Alarm
1024 CO2 Alarm
2048 Heat Alarm
4096 Water Alarm
8192 Access Control
16384 Home Security
Value 0 and 1 cannot be used at the same time, choose one as a part of your calculation.
Use the sum of values to determine what alarms trigger your Smart Switch 7.
For example:
Value = 0 + 256 + 512 + 1024 = 1792
0 = sets the control scheme to turn on Smart Switch 7 when open alarm state happens
256 = allows Smoke Alarm signals to control SS7
512 = allows CO Alarm signals to control SS7
1024 = allows CO2 Alarm signals to control SS7
Parameter 10 - Release/Disable alarm.
Sets how you are able to disable Smart Switch 7s alarm state.
Size = 1 Byte
Default Setting = 0
Value Description
0
Tap 3 times to disable the
alarm state.
1 Notification idle events.
10 - 255
Sets time in minutes on
how long the alarm state
should be held.
Parameter 18 - Flash frequency.
Configures the LED flash frequency and amount of time.
Size = 2 Byte
Default Setting = 0x0002 or 2
Byte
Value
Description
(MSB
Value 1)
1 - 9
Sets the flash frequency in
seconds. (Default = 0x0002
or 2)
Parameter 19 - Start/Stop LED flash (Write Only)
Sets the timeframe of flashing in seconds
Size = 2 Byte
Default Setting = 0 (disables LED flash during alarm)
Value Description
0 Stop flashing
1 - 255
Set the duration in
seconds and start the
blinking process.