Parameter 12: Over Light Group Threshold (Group5)
Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light < (this value) send BASIC_SET
(0x00) to associated devices.
Size: 2 Byte, Default Value: 2000
Setting Description
0 disable
1 - 30000 Lux
Parameter 13: Under Light Group Threshold (Group6)
Set threshold of Light/Lux. If measured light/lux <= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux > (this value) send
BASIC_SET (0x00) to associated devices.
Size: 2 Byte, Default Value: 100
Setting Description
0 disable
1 - 30000 Lux
Parameter 14: Low Battery Threshold
Configure low battery report threshold, sends low battery report via notification and battery report when battery level drops under setting. Unit %.
Size: 1 Byte, Default Value: 20
Setting Description
10 - 50 %
Parameter 15: Threshold Check Enable/Disable
Size: 1 Byte, Default Value: 0
Setting Description
0 disable
1 enable
Parameter 16: Temperature Threshold
Size: 1 Byte, Default Value: 30
Setting Description
0 disable
1 - 255 Value x 0,1
Parameter 17: Lux Threshold
Size: 2 Byte, Default Value: 250
Setting Description
0 disable
0 - 10000 Lux
Parameter 18: Threshold Check Time
Set threshold check time in seconds.
Size: 2 Byte, Default Value: 900
Setting Description
60 - 65535 Time in seconds
Parameter 19: Sensor Limit Control
This value is bit mask. Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value.
(1+2=3)
Size: 1 Byte, Default Value: 0
Setting Description
0 Disable
1 Temperature upper level
2 Lux upper level
4 Temperature lower level
8 Lux lower level