Parameter 20: Temperature Upper Limit
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param23. If (Current measurement) > (Upper Limit), then report sensor.
Size: 2 Byte, Default Value: 280
Setting Description
280 - 1000 °C
824 - 2120 °F
Parameter 21: Temperature Lower Limit
Set lux upper limit level. If (Current measurement) > (Upper Limit), then report sensor.
Size: 2 Byte, Default Value: 0
Setting Description
-400 - 0 °C
-400 - 320 °F
Parameter 22: Lux Upper Limit
Set Lux upper limit level. If (Current measurement) > (Upper Limit), then report sensor.
Size: 2 Byte, Default Value: 1000
Setting Description
0 - 30000 Lux
Parameter 23: Lux lower limit level.
Set Lux lower limit level. If (Current Measurement) < (Lower limit), then report sensor.
Size: 2 Byte, Default Value: 100
Setting Description
0 - 30000 Lux
Parameter 24: Temperature Scale
Set the scale for temperature when reports.
Size: 1 Byte, Default Value: 0
Setting Description
0 °C
1 °F
Parameter 25: Automatic Interval Time
Interval time set in seconds to check the sensor report. Multilevel Sensor Report will be sent when timeout
Size: 2 Byte, Default Value: 3600
Setting Description
30 - 65535 Time in seconds
Technical Data
Dimensions 0.0450000x0.0450000x0.0400000 mm
Weight 22 gr
Hardware Platform EFR32ZG23
EAN 1220000017276
IP Class IP IP20
Battery Type 1 * CR123A
Device Type Sensor
Firmware Version 02.07
Z-Wave Version 07.12
Certification ID ZC14-24010390
Z-Wave Product Id 0371.0002.002d
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
Supported Command Classes