3718.01._5280107_02
NRL 0280-0750 °-L / A-E
EN
NRL
Gx Gy 1 2 3 4 5 6 7 8
00 976 505 1.310 30,1% 25,5% - - 24,0% 20,4% - - 13
02 - 04 1640 523 1.585 24,3% 22,0% - - 28,2% 25,6% - - 10
01 - 03 1623 523 1.572 24,5% 22,2% - - 28,0% 25,3% - - 10
P2 - P4 1010 507 1.361 29,1% 24,8% - - 24,9% 21,2% - - 13
P1 - P3 993 506 1.336 29,6% 25,2% - - 24,5% 20,8% - - 13
00 980 504 1.306 30,2% 25,5% - - 24,0% 20,3% - - 13
02 - 04 1644 523 1.582 24,3% 22,0% - - 28,1% 25,5% - - 10
01 - 03 1627 522 1.569 24,6% 22,2% - - 27,9% 25,3% - - 10
P2 - P4 1014 506 1.357 29,2% 24,8% - - 24,8% 21,1% - - 13
P1 - P3 997 505 1.332 29,7% 25,2% - - 24,4% 20,7% - - 13
00 1166 547 1.331 27,6% 27,3% - - 22,7% 22,4% - - 13
02 - 04 1832 548 1.571 23,5% 23,3% - - 26,7% 26,5% - - 10
01 - 03 1814 548 1.559 23,7% 23,5% - - 26,5% 26,3% - - 10
P2 - P4 1202 547 1.376 26,8% 26,5% - - 23,4% 23,2% - - 13
P1 - P3 1184 547 1.354 27,2% 26,9% - - 23,1% 22,8% - - 13
00 1181 547 1.322 27,7% 27,4% - - 22,5% 22,3% - - 13
02 - 04 1847 548 1.564 23,6% 23,4% - - 26,6% 26,4% - - 10
01 - 03 1829 548 1.551 23,8% 23,6% - - 26,4% 26,2% - - 10
P2 - P4 1217 547 1.366 27,0% 26,7% - - 23,3% 23,0% - - 13
P1 - P3 1199 547 1.345 27,4% 27,1% - - 22,9% 22,7% - - 13
00 1359 545 1.903 7,1% 7,0% 31,6% 31,0% 11,7% 11,5% - - 22
02 - 04 2025 547 2.079 3,4% 3,4% 34,7% 34,3% 12,2% 12,0% - - 22
01 - 03 2007 547 2.068 3,5% 3,4% 34,8% 34,4% 12,0% 11,9% - - 22
P2 - P4 1395 545 1.938 6,9% 6,8% 31,4% 30,8% 12,2% 11,9% - - 22
P1 - P3 1377 545 1.921 7,0% 6,9% 31,5% 30,9% 12,0% 11,7% - - 22
00
1699 732 1.909 9% 10% 15% 15% 23% 24% 3% 3% 23
02 - 04
2669 739 2.124 6% 6% 14% 15% 27% 28% 2% 2% 23
01 - 03
2609 739 2.097 6% 7% 15%
15% 27% 28% 2% 2% 23
P2 - P4
1819 734 1.999 9% 9% 13% 14% 24% 25% 3% 3% 23
P1 - P3
1759 733 1.955 9% 9% 14% 15% 23% 24% 3% 3% 23
Gy
Gx
1
3
2
4
Top View
Gy
Gy
Gx
1
2
3
4
5
6
1
2
3
4
5
6
7
8
Top View Top View
The units are completely wired at the factory and only
from a unit switch, according to that envisioned by
the Standards in force on this subject in the country of
installation.
It Is also advised to check that:
1. The electrical mains features are suitable for the
input values indicated in the electrical data table,
also taking any other machines operating at the
same time into consideration.
2. The unit must only be powered when installation
3. Respect the connection indications of the phase
and grounding wires.
4. The power supply line must have a relevant
protection against short circuits mounted upstream
and dispersions to grounding, which isolate the
system with respect to other utilities.
5. The voltage must be within a tolerance of ±10% of
the nominal power supply voltage of the machine
not respected, contact the electric energy public
body.
6. For electric connections, use the cables with
double isolation according to the Standards in force
on this subject in the different countries.
1. The use of an omnipolar magnet circuit breaker
switch is mandatory, in compliance with the IEC-EN
suitable cut-off power and differential protection
on the basis of the electric data table shown below,
installed as near as possible to the appliance.
2. It is mandatory to make an effective grounding
connection. The manufacturer is not liable for
any damage caused by the lack of or ineffective
appliance grounding connection.
3. For units with three-phase power supply, check the
correct connection of the phases.
4. It is mandatory to verify that the machine is
electrical works have been completed.
, suitably trained and informed on the risks related
The features of the electrical lines and of the related
components must be determined by
in compliance with
diagram supplied with the appliance.
1. It is prohibited to use the water pipes to earth the
appliance.
2. Check the tightening of all power wire clamps on
commissioning and after 30 days from start-up.
Successively check them every six months.
cables and components.
1.
open.
2. Open the front panel.
3. Use the plates to pass the main electric power
supply cable and the cables of the other
the installer.
4.
envisioned in this manual with electric cables.
5. Avoid direct contact with non-insulated copper
piping and with the compressor.
6.
and always refer exclusively to the wiring
diagram supplied with the unit.
7.
the power supply cable to the electric control
board inside the unit and connect it to clamps.
L1-L2-L3 as phases, and PE as grounding;
8.
9.
powering the unit electrically.
10.
ON
OFF
Holes for passage of electric cables
Master Switch ON/OFF
Restoring the
protection degree of
the electrical box by
the installer
10.