MODEL: AP80RVL
BATHROOM FAN
www.aeropurefans.com
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. This product is designed for installation
in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must be horizontal. ** DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4. Please read
specification label on product for further information and requirements.
For quiet and efficient operation, long life, and attractive appearance lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling.
OPERATION
Use an on/off switch to operate this fan. See “Connect Wiring” for details.
PLAN THE INSTALLATION
1. Do not use in a cooking area.
2. Two ways to connect ductwork to a factory-shipped unit.
INSULATION*
(Place around and
ROOF CAP*
over Fan Housing.)
(with built-in
damper)
FAN
POWER
HOUSING
CABLE*
Keep duct
runs short
Seal gaps
around
Housing.
ROUND
DUCT*
WALL CAP*
Seal duct
(with built-in
* Purchase
joints with
ROUND
damper)
separately
tape.
ELBOW(S) *
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number
listed in the warranty. 2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power
from being switching on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel. 3. Installation work and electrical wiring must be done by a licensed person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault
Circuit Interrupter) - protected branch circuit. 8. This unit must be grounded. 9. Never place a switch where it can be reached from a tub or shower.
10. Not for use in kitchens. 11. Install fan at least 2.5 m (8.2 feet) above the floor. 12. WARNING: To reduce the risk of fire or electric shock,
do not use this fan with any solid-state speed control device. 13. The fan must not be installed in a ceiling thermally insulated to a value greater than
R40.
Question and Answer IconNeed help?

Do you have a question about the aero pure AP80RVL and is the answer not in the manual?

Summary

Important Safety Warnings

General Safety Precautions

Instructions to reduce risk of fire, electric shock, or injury. Includes proper installation and usage guidelines.

Cautions for Use and Installation

Advises on general ventilating use, installation limitations, and avoiding motor damage.

Cleaning and Maintenance Guidelines

Provides instructions for cleaning the unit and notes that the motor is permanently lubricated.

Operating the Fan

Details on how to operate the fan using an on/off switch.

Installation Planning

Key considerations before installation, including location and duct connection methods.

Assembly and Installation Procedures

Mounting with Hanger Bars

Step-by-step guide on how to mount the fan housing using the provided hanger bars.

Installing Round Ductwork

Instructions for connecting ductwork to the fan and venting it outdoors, ensuring airtight connections.

Electrical Wiring Connection

Guide for connecting the 120 Volts AC house wiring to the fan unit using approved connectors.

Finishing and Replacement Tasks

Finishing Ceiling Connections

Details on cutting the ceiling hole, sealing gaps, and installing the bulb.

Component Replacement Steps

Instructions for removing and replacing components like the trim ring, lamp base, and blower system.

Capacitor Replacement

Procedure for replacing the fan's capacitance by accessing the wire panel.

Service Parts and Warranty

Service Parts Identification

Lists and identifies all available service parts for the unit.

Product Warranty Information

Details the warranty coverage, exclusions, and limitations for the product.

Overview

This document provides comprehensive instructions for the installation, operation, and maintenance of the Aero Pure AP80RVL Bathroom Fan. It is designed to ensure safe and efficient use, offering guidance for both installers and homeowners.

The Aero Pure AP80RVL is a bathroom fan primarily intended for general ventilating use. Its main function is to exhaust air from bathrooms, helping to reduce humidity, odors, and prevent the buildup of moisture that can lead to mold and mildew. The fan is designed for ceiling installation and is suitable for ceilings with up to a 12/12 pitch (45-degree angle). It is important to note that this fan should not be mounted in a wall or used in cooking areas, nor should it be used to exhaust hazardous or explosive materials and vapors. The fan is also not intended for use with solid-state speed control devices.

Key usage features include its suitability for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit, enhancing safety in wet environments. The unit must be properly grounded to prevent electric shock. For optimal performance and safety, the fan should be installed at least 2.5 meters (8.2 feet) above the floor. The design allows for the use of a compact fluorescent bulb or LED bulb, although the bulb itself is not included. The bulb housing is adjustable to accommodate different bulb types, and the unit is qualified for use with G24 adaptors and GU24 bulbs.

Installation involves several steps, starting with mounting the fan housing using sliding hanger bars. These bars are designed to fit various framing types, including I-joist, standard joist, and truss construction, allowing for accurate positioning between framing members. Once positioned, the hanger bars are secured to the framing with screws. Ductwork connection is a critical step; the fan requires round ductwork (not included) to vent to the outdoors, either to a roof or wall cap. Insulated flexible duct is recommended for the quietest possible operation, with a 1-3 foot run of rigid duct followed by insulated flexible duct ensuring the quietest performance. All ductwork connections must be sealed with duct tape to ensure they are airtight. Electrical wiring involves connecting 120 Volts AC house wiring to the fan using UL-approved connectors, following the provided wiring diagrams for proper connection of the fan and light components. A round ceiling hole of 6 1/2 inches (165mm) diameter must be cut, and any gaps between the drywall and the fan flange should be sealed with caulk or other sealant to prevent air leakage.

Maintenance features are designed for simplicity and longevity. The motor is permanently lubricated and does not require oiling, reducing the need for regular servicing. For quiet and efficient operation, as well as to maintain an attractive appearance, the grille should be lowered or removed periodically to allow for vacuuming of the interior of the unit with a dusting brush attachment. This helps prevent the accumulation of dust and debris that could impede performance. During installation, it is crucial to keep drywall spray, construction dust, and other foreign materials off the power unit to prevent motor bearing damage and noisy or unbalanced impellers.

The product comes with a warranty covering defects in workmanship and materials for the mechanical and electrical parts for a period of 72 months from the date of purchase. This warranty is extended to the original retail purchaser and requires proof of purchase. The manufacturer will replace any defective mechanical or electrical part under normal household use. However, the warranty does not cover damages resulting from improper installation, shipping, misuse, abuse, accident, alteration, lack of proper care, maintenance, or service by unlicensed electricians. It also excludes labor or transportation charges related to repairs and does not cover fluorescent lamp starters, tubes, or light bulbs. This limited warranty is provided in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. It offers an exclusive remedy and does not cover incidental or consequential damages, though specific legal rights may vary by state.

Replacement installation instructions are also provided, detailing how to remove and replace various components such as the trim ring, screws, lamp base, blower system, and capacitance. This ensures that users can maintain and repair the fan effectively should parts need to be exchanged. The manual emphasizes the importance of reading and saving these instructions, and installers are requested to leave the manual with the homeowner for future reference.

aero pure AP80RVL Specifications

General IconGeneral
TypeExhaust Fan
ModelAP80RVL
Airflow80 CFM
Duct Size4 inches
Voltage120V
CategoryFan
Frequency60 Hz
Speed Settings1
MaterialPlastic
FeaturesEnergy Star Certified
Power SourceElectric