VENTILATION FAN
MODEL: AP90-SL & AP90H-SL
AP120-SL & AP120H-SL
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or
telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be
done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and
standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or
shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit (ceiling installation only). 8. This unit
must be grounded. 9. Never place a switch where it can be reached from a tub or shower. 10. Not for use in kitchens. This unit may
be installed in a wall for a non- wet application. 11. Install fan at least 2.5 m (8 feet) above the floor. 12 WARNING: To reduce the risk
of fire or electric shock, do not use this fan with any solid-state speed control device. 13. The fan must not be installed in a ceiling
thermally insulated to a value greater than R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for wall
application.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust off power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling.
OPERATION
See “Connect Wiring” for details. (AP90/120-SL)
The humidity control and fan and light can be operated separately. Do not use a dimmer switch to operate the humidity control or
light. See “Connect Wiring” for details. (AP90/120H-SL)
Humidity Sensor For AP90/120H-SL
SENSOR OPERATION
The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable)
increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). The humidity sensor
may occasionally turn the fan ON when environmental conditions change. If the fan continuously responds to changing
environmental conditions, “H” (means “humidity”) adjustment may be required. This figure is factory-set for about 75% RH.
SENSITIVITY ADJUSTMENT
The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness
control, the “H” may need to be increased toward maximum “+”. If the control is responding too often to changing
environmental conditions, movement toward less “-” “H” may be required.
To adjust the “H”:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward “+” or “-”.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.
5. Repeat above steps if necessary.
When the temperature changes, humidity sensor values will have deviation.
TIMER ADJUSTMENT
The humidity sensing fan has a “T” (means timer) that can be adjusted from 5 to 60 minutes (factory-set at about 20 minutes).
This “T” controls the length of time that the fan remains ON after the sensor has stopped sensing a rise in humidity
and the humidity level is below the user-adjustable set-point. To adjust the “T”:
1. Disconnect power at service entrance;
2. Through the grille, locate the slot marked “T”;
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes).
4. Check operation by turning on a humidity source until the fan turns on.
5. Turn humidity source off and time the unit.
6. Repeat above steps if necessary.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner
Question and Answer IconNeed help?

Do you have a question about the aero pure AP90-SL and is the answer not in the manual?

Summary

General Safety Precautions

Safety Warning for Fire, Shock, Injury

Essential safety instructions to prevent fire, electric shock, or injury during installation and use.

Usage and Installation Cautions

Ventilation and Installation Guidelines

Important guidelines for proper and safe use, including ventilation and installation limitations.

Cleaning and Maintenance Procedures

Unit Cleaning and Motor Lubrication

Instructions for maintaining the unit for optimal performance and longevity.

Operation and Adjustments

Humidity Sensor and Timer Operation

Details on how to adjust and operate the humidity sensor and timer functions.

Sensitivity Adjustment

Guidance on adjusting the humidity sensor's sensitivity to environmental changes.

Timer Adjustment

Instructions for setting the fan's run time after humidity levels normalize.

Installation Planning and Assembly

Installation Location and Ductwork

Guidance on selecting installation locations and connecting ductwork for optimal performance.

Mounting Methods and Hardware

Detailed steps and options for securely mounting the fan housing using hanger bars.

Assembly and Wiring Instructions

Ductwork Installation

Instructions for connecting and installing the ductwork for proper ventilation.

Electrical Wiring Connection

Diagrams and steps for connecting the fan's electrical wiring to the power supply.

Grille Installation

Procedure for attaching the grille assembly to the fan housing after installation.

Service Parts and Warranty

Replacement Parts List

List of available replacement parts for the ventilation fan.

Warranty Coverage and Limitations

Details on the product warranty, including coverage, exclusions, and remedies.

Overview

This document describes the Aero Pure Ventilation Fan, models AP90-SL, AP90H-SL, AP120-SL, and AP120H-SL.

Function Description:

The Aero Pure Ventilation Fan is designed for general ventilating use, primarily in bathrooms. It helps to exhaust air, control humidity, and prevent backdraft when properly installed. The "H" models (AP90H-SL, AP120H-SL) include a sophisticated humidity sensor and a timer function, allowing for automatic operation based on environmental humidity levels. The fan is suitable for installation in ceilings up to a 12/12 pitch (45-degree angle) and can also be installed in a wall for non-wet applications. It is acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit (ceiling installation only).

Important Technical Specifications:

  • Models: AP90-SL, AP90H-SL, AP120-SL, AP120H-SL.
  • Power Supply: 120V AC.
  • Installation: Designed for ceilings up to a 12/12 pitch (45-degree angle). Wall installation is possible for non-wet applications.
  • Minimum Installation Height: Must be installed at least 2.5 m (8 feet) above the floor.
  • Ductwork: Requires round ductwork, vented to the outdoors. Insulated flexible duct is recommended for quietest operation.
  • Humidity Sensor (H-models): Responds to rapid to moderate increases in humidity or humidity above a user-adjustable set-point (50%-100% relative humidity). Factory-set for approximately 75% RH.
  • Timer (H-models): Adjustable from 5 to 60 minutes, factory-set at about 20 minutes.
  • Grounding: The unit must be grounded.
  • Insulation: Not to be installed in a ceiling thermally insulated to a value greater than R40.
  • Speed Control: Not to be used with any solid-state speed control device.

Usage Features:

  • Safety Precautions:
    • Always read the manual before use.
    • Switch power off at the service panel and lock out before servicing or cleaning.
    • Installation and wiring must comply with all applicable codes and standards, including fire-rated construction codes.
    • Ensure sufficient air for combustion and exhausting of gases from fuel-burning equipment to prevent backdraft.
    • Avoid damaging electrical wiring or hidden utilities when cutting or drilling into walls/ceilings.
    • Never place a switch where it can be reached from a tub or shower.
    • Not for use in kitchens.
    • Do not use to exhaust hazardous or explosive materials and vapors.
    • Keep drywall and construction dust off the power unit to prevent motor bearing damage and noisy/unbalanced impellers.
  • Installation:
    • Not to be used in a cooking area.
    • Duct connector must point up for wall application.
    • Mounting options include using mounting holes with hanger bars, hanger bars only, or mounting to I-joists. Hanger bars are adjustable to fit various framing widths.
    • Ductwork connections should be air-tight using duct tape.
    • Electrical wiring (120V AC) should be connected using UL-approved connectors according to the provided wiring diagrams.
    • The grille assembly is attached by pinching springs and positioning it into the housing slots, then gently pushing it towards the ceiling.
  • Operation (AP90/120-SL): The fan and light can be operated separately. A dimmer switch should not be used for the light.
  • Operation (AP90/120H-SL - Humidity Sensor Models):
    • The humidity control, fan, and light can be operated separately.
    • Humidity Sensor Adjustment ("H"): The sensitivity of the humidity sensor can be adjusted to respond more or less frequently to changing environmental conditions.
      • To adjust: Disconnect power, locate the "H" slot through the grille, rotate the adjustment toward "+" (more sensitive) or "-" (less sensitive), then restore power and test.
    • Timer Adjustment ("T"): The fan's run-on time after humidity sensing stops can be adjusted.
      • To adjust: Disconnect power, locate the "T" slot through the grille, rotate the adjustment to the desired setting (5-60 minutes), then restore power and test.

Maintenance Features:

  • Cleaning: For quiet and efficient operation, long life, and attractive appearance, the grille should be lowered or removed, and the interior of the unit vacuumed with a dusting brush attachment.
  • Lubrication: The motor is permanently lubricated and never needs oiling.
  • Parts Replacement: Service parts are available, including grille assembly, grille springs, humidity sensor (for H-models), motor plate, motor, blower wheel, wire panel/harness assembly, hanger bar kit, wiring plate, housing, and damper/duct connector. Instructions are provided for replacing blower assembly components (motor, motor plate, etc.) by removing screws and pushing down a rib in the plate. Always disconnect power before replacing parts.

Warranty:

A 72-month warranty covers defects in workmanship or materials for the mechanical and electrical parts from the date of purchase. The original sales receipt is required as proof of purchase. The manufacturer will replace defective parts under normal household use. The warranty does not cover:

  • Damages from improper installation, shipping, misuse, abuse, accident, alteration, lack of proper care, or maintenance.
  • Damages from service by persons other than a licensed electrician.
  • Labor or transportation charges related to product repair.
  • Fluorescent lamp starters and tubes. This limited warranty is exclusive and in lieu of all other warranties, expressed or implied, including merchantability and fitness for a particular purpose. It does not cover incidental or consequential damages. Specific legal rights may vary by state.