EasyManua.ls Logo

aero pure AP90-SL User Manual

aero pure AP90-SL
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VENTILATION FAN
MODEL: AP90-SL & AP90H-SL
AP120-SL & AP120H-SL
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or
telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be
done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and
standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or
shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit (ceiling installation only). 8. This unit
must be grounded. 9. Never place a switch where it can be reached from a tub or shower. 10. Not for use in kitchens. This unit may
be installed in a wall for a non- wet application. 11. Install fan at least 2.5 m (8 feet) above the floor. 12 WARNING: To reduce the risk
of fire or electric shock, do not use this fan with any solid-state speed control device. 13. The fan must not be installed in a ceiling
thermally insulated to a value greater than R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for wall
application.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust off power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling.
OPERATION
See “Connect Wiring” for details. (AP90/120-SL)
The humidity control and fan and light can be operated separately. Do not use a dimmer switch to operate the humidity control or
light. See “Connect Wiring” for details. (AP90/120H-SL)
Humidity Sensor For AP90/120H-SL
SENSOR OPERATION
The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable)
increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). The humidity sensor
may occasionally turn the fan ON when environmental conditions change. If the fan continuously responds to changing
environmental conditions, “H” (means “humidity”) adjustment may be required. This figure is factory-set for about 75% RH.
SENSITIVITY ADJUSTMENT
The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness
control, the “H” may need to be increased toward maximum “+”. If the control is responding too often to changing
environmental conditions, movement toward less “-” “H” may be required.
To adjust the “H”:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward “+” or “-”.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.
5. Repeat above steps if necessary.
When the temperature changes, humidity sensor values will have deviation.
TIMER ADJUSTMENT
The humidity sensing fan has a “T” (means timer) that can be adjusted from 5 to 60 minutes (factory-set at about 20 minutes).
This “T” controls the length of time that the fan remains ON after the sensor has stopped sensing a rise in humidity
and the humidity level is below the user-adjustable set-point. To adjust the “T”:
1. Disconnect power at service entrance;
2. Through the grille, locate the slot marked “T”;
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes).
4. Check operation by turning on a humidity source until the fan turns on.
5. Turn humidity source off and time the unit.
6. Repeat above steps if necessary.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner
Question and Answer IconNeed help?

Do you have a question about the aero pure AP90-SL and is the answer not in the manual?

aero pure AP90-SL Specifications

General IconGeneral
Brandaero pure
ModelAP90-SL
CategoryFan
LanguageEnglish

Summary

General Safety Precautions

Safety Warning for Fire, Shock, Injury

Essential safety instructions to prevent fire, electric shock, or injury during installation and use.

Usage and Installation Cautions

Ventilation and Installation Guidelines

Important guidelines for proper and safe use, including ventilation and installation limitations.

Cleaning and Maintenance Procedures

Unit Cleaning and Motor Lubrication

Instructions for maintaining the unit for optimal performance and longevity.

Operation and Adjustments

Humidity Sensor and Timer Operation

Details on how to adjust and operate the humidity sensor and timer functions.

Sensitivity Adjustment

Guidance on adjusting the humidity sensor's sensitivity to environmental changes.

Timer Adjustment

Instructions for setting the fan's run time after humidity levels normalize.

Installation Planning and Assembly

Installation Location and Ductwork

Guidance on selecting installation locations and connecting ductwork for optimal performance.

Mounting Methods and Hardware

Detailed steps and options for securely mounting the fan housing using hanger bars.

Assembly and Wiring Instructions

Ductwork Installation

Instructions for connecting and installing the ductwork for proper ventilation.

Electrical Wiring Connection

Diagrams and steps for connecting the fan's electrical wiring to the power supply.

Grille Installation

Procedure for attaching the grille assembly to the fan housing after installation.

Service Parts and Warranty

Replacement Parts List

List of available replacement parts for the ventilation fan.

Warranty Coverage and Limitations

Details on the product warranty, including coverage, exclusions, and remedies.

Related product manuals