Subject to Export Control, see Cover Page for details. C-19
C-4. REMOTE OPERATION COMMANDS (cont)
Deviation Meter / Modulation Meter
COMMAND RANGE DESCRIPTION
:devmod:alarm:high:limit AM - 0.0% to 100%
FM - 0.0 to 100.0 kHz
Sets Alarm high limit value.
:devmod:alarm:high:limit? Returns Alarm high limit value.
:devmod:alarm:high:state Sets Alarm high limit state.
:devmod:alarm:high:state? Returns Alarm high limit state.
:devmod:alarm:low:limit AM - 0.0% to 100%
FM - 0.0 to 100.0 kHz
Sets Alarm low limit value.
:devmod:alarm:low:limit? Returns Alarm low limit value.
:devmod:alarm:low:state Sets Alarm low limit state.
:devmod:alarm:low:state? Returns Alarm low limit state.
:devmod:average 1 to 99 Sets number of readings to average.
:devmod:average? Returns number of readings to average.
:devmod:range:am:auto Sets Modulation Meter autorange state to
Auto.
:devmod:range:am:manual Sets Modulation Meter autorange state to
Manual.
:devmod:range:am:range? Returns Modulation Meter range information.
:devmod:range:am:state? 0 - Auto
1 - Manual
2 - Manual - Waiting Update
Returns Modulation Meter autorange state.
:devmod:range:fm:auto Sets Modulation Meter autorange state to
Auto.
:devmod:range:fm:manual Sets Modulation Meter autorange state to
Manual.
:devmod:range:fm:range? Returns Modulation Meter range information.
:devmod:range:fm:state? 0 - Auto
1 - Manual
2 - Manual - Waiting Update
Returns Modulation Meter autorange state.
:devmod:reading:avg? AM - 0.0% to 100%
FM - 0.0 to 100.0 kHz
Returns Modulation Meter reading new
average Peak2Peak value.
:devmod:reading:clear Clears Meter reading.
:devmod:reading:max? AM - 0.0% to 100%
FM - 0.0 to 100.0 kHz
Returns Modulation Meter reading maximum
value.
:devmod:reading:min? AM - 0.0% to 100%
FM - 0.0 to 100.0 kHz
Returns Modulation Meter reading minimum
value
:devmod:reading:peak2peak? AM - 0.0% to 100%
FM - 0.0 to 100.0 kHz
Returns Modulation Meter reading
Peak2Peak value.
:devmod:reading:pk_state Enables/disables reading Peak Hold function.
:devmod:reading:type 0 - PEAK_READING_PLUS
1 - PEAK_READING_MINUS
2 - PK_PK_READING
Selects readings sent to CF Meter.
:devmod:reading:type? Returns readings sent to CF Meter.
:devmod:reading:val? AM - 0.0% to 100%
FM - 0.0 to 100.0 kHz
Returns Modulation Meter reading current
average Peak2Peak value.
:devmod:type 0 - AM
1 - FM
Sets Meter Type.
:devmod:type? Returns Meter Type.