C-20 Subject to Export Control, see Cover Page for details.
C-4. REMOTE OPERATION COMMANDS (cont)
Distortion Meter
COMMAND RANGE DESCRIPTION
:distortion:demod:alarm:high:limit 0.0% to 100% Sets Alarm high limit value.
:distortion:demod:alarm:high:limit? Returns Alarm high limit value.
:distortion:demod:alarm:high:state Sets Alarm high limit state.
:distortion:demod:alarm:high:state? Returns Alarm high limit state.
:distortion:demod:alarm:low:limit 0.0% to 100% Sets Alarm low limit value.
:distortion:demod:alarm:low:limit? Returns Alarm low limit value.
:distortion:demod:alarm:low:state Sets Alarm low limit state.
:distortion:demod:alarm:low:state? Returns Alarm low limit state.
:distortion:demod:average 1 to 99 Sets number of readings to
average.
:distortion:demod:average? Returns number of readings to
average.
:distortion:demod:reading:avg? 0.0% to 100% Returns Distortion Meter reading
with averaged value.
:distortion:demod:reading:clear Clear Distortion Meter reading.
:distortion:demod:reading:max? 0.0% to 100% Returns Distortion Meter reading
maximum value.
:distortion:demod:reading:min? 0.0% to 100% Returns Distortion Meter reading
minimum value.
:distortion:demod:reading:val? 0.0% to 100% Returns Distortion Meter average
value.
:distortion:demod:state Activates Distortion Meter on
demod input.
:distortion:demod:state? Returns Distortion Meter state on
demod input.
:distortion:ext_aud_in:alarm:high:limit 0.0% to 100% Sets Alarm high limit value.
:distortion:ext_aud_in:alarm:high:limit? Returns Alarm high limit value.
:distortion:ext_aud_in:alarm:high:state Sets Alarm high limit state.
:distortion:ext_aud_in:alarm:high:state? Returns Alarm high limit state.
:distortion:ext_aud_in:alarm:low:limit 0.0% to 100% Sets Alarm low limit value.
:distortion:ext_aud_in:alarm:low:limit? Returns Alarm low limit value.
:distortion:ext_aud_in:alarm:low:state Sets Alarm low limit state.
:distortion:ext_aud_in:alarm:low:state? Returns Alarm low limit state.
:distortion:ext_aud_in:average 1 to 99 Sets number of readings to
average.
:distortion:ext_aud_in:average? Returns number of readings to
average.
:distortion:ext_aud_in:filter 0 - No Filter
1 - 15 kHz LP
2 - 300 Hz to 3 kHz BP
Sets audio filter status.
:distortion:ext_aud_in:filter? Returns audio filter status.
:distortion:ext_aud_in:reading:avg? 0.0% to 100% Returns Distortion Meter reading
with averaged value.
:distortion:ext_aud_in:reading:clear Clear Distortion Meter reading.
:distortion:ext_aud_in:reading:max? 0.0% to 100% Returns Distortion Meter reading
maximum value.
:distortion:ext_aud_in:reading:min? 0.0% to 100% Returns Distortion Meter reading
minimum value.
:distortion:ext_aud_in:reading:val? 0.0% to 100% Returns Distortion Meter average
value.
:distortion:ext_aud_in:state Activates Distortion Meter on ext
audio input.