C-30 Subject to Export Control, see Cover Page for details.
C-4. REMOTE OPERATION COMMANDS (cont)
RSSI Meter
COMMAND RANGE DESCRIPTION
:rssi:alarm:high:limit 0 to 20 W Sets Alarm high limit value.
:rssi:alarm:high:limit? Returns Alarm high limit value.
:rssi:alarm:high:state Sets Alarm high limit state.
:rssi:alarm:high:state? Returns Alarm high limit state.
:rssi:alarm:low:limit 0 to 20 W Sets Alarm low limit value.
:rssi:alarm:low:limit? Returns Alarm low limit value.
:rssi:alarm:low:state Sets Alarm low limit state.
:rssi:alarm:low:state? Returns Alarm low limit state.
:rssi:average 1 to 99 Sets number of readings to average.
:rssi:average? Returns number of readings to average.
:rssi:range:dbm:auto Sets Audio Level autorange state to Auto.
:rssi:range:dbm:manual Sets Audio Level autorange state to Manual.
:rssi:range:dbm:range? Returns Audio Level range information.
:rssi:range:dbm:state? 0 - Auto
1 - Manual
2 - Manual - Waiting Update
Returns Audio Level autorange state.
:rssi:range:watts:auto Sets Audio Level autorange state to Auto.
:rssi:range:watts:manual Sets Audio Level autorange state to Manual.
:rssi:range:watts:range? Returns Audio Level range information.
:rssi:range:watts:state? 0 - Auto
1 - Manual
2 - Manual - Waiting Update
Returns Audio Level autorange state.
:rssi:reading:avg? -110 to 43 dBm Returns RSSI reading averaged value.
:rssi:reading:dbm:avg? -110 to 43 dBm Returns RSSI reading averaged value.
:rssi:reading:dbm:max? -110 to 43 dBm Returns RSSI reading maximum value.
:rssi:reading:dbm:min? -110 to 43 dBm Returns RSSI reading minimum value.
:rssi:reading:dbm:val? -110 to 43 dBm Returns RSSI reading with no statistics.
:rssi:reading:clear Clears RSSI reading.
:rssi:reading:max? -110 to 43 dBm Returns RSSI reading maximum value.
:rssi:reading:min? -110 to 43 dBm Returns RSSI reading minimum value.
:rssi:reading:units 0 - dBm
1 - Watts
2 - μWatts
Sets displayed units.
:rssi:reading:val? -110 to 43 dBm Returns RSSI reading with no statistics.
:rssi:reading:watt:avg? 0 to 20 W Returns RSSI reading averaged value.
:rssi:reading:watt:max? 0 to 20 W Returns RSSI reading maximum value.
:rssi:reading:watt:min? 0 to 20 W Returns RSSI reading minimum value.
:rssi:reading:watt:val? 0 to 20 W Returns RSSI reading with no statistics.
:rssi:state Activates RSSI readings.
:rssi:state? Returns state of RSSI Meter.