TROUBLESHOOTING AND FAULT REPAIR (Cont.)
No.
Symptom
Probable Causes
Remedy
7
Breeze S does not
move when
squeezing the
Operating Lever .
Main Key Switch
is in OFF position.
Charging Plug
is installed in
Charging Socket.
The Mechanical
Release Lever of the
electromagnetic
Brake is operated .
Other inhibit :
Panic brake.
Control system
failure.
Turn the key to
“ON” position.
Disconnect the
Charging Plug from the
Breeze S.
Remove lever to
engaged position .
Reset by switch
OFF and ON again.
Call for technical
support.
8
Intermittent drive.
Battery capacity
low.
Failed
connections
Faulty battery.
Charge batteries for
at least 18 hours.
Remove Batteries
Cover and check the
battery cables
connection. In case of
corrosion of the
terminals, clean the
terminals with a damp
clean cloth.
If, after recharge,
the red leds are still ON,
the battery may be
faulty. For replacement,
contact your dealer.
9
Main or rear lights or
Blinkers light are
inoperative.
Faulty LED light
board or Electronics
fault.
Call technician for
assistance.
10
When driving uphill or
carrying heavy loads
the Breeze S speed is
decreased gradually
but still moving.
The
Breeze S controller
exceeded too high
temperature.
It is recommended
to stop the Breeze S
and let the controller
cool for awhile.