Zero-Injection Wiring
04
The distance between the inverter and smart meter is suggested sless
than 100M. For the distance more than 100M, it needs to parallel a
120Ω resistor between 24A and 25B of the smart meter.
Note:
Single-phase Smart Meter
Three-phase Smart Meter
24A 25B
24A 25B
24A 25B