C1: C1 is the vibration cal number. This number represents some
minimum value that the sensors must output before cotton flow is
calculated. Any signal below this value will not be recorded and cannot
be modified by post calibration. This is the number to be adjusted if a
significant amount of cotton is accumulating when sitting still in
logging mode. (this value should only be adjusted after all other
possible sources are ruled out.) Increase the value to decrease the
influence of vibration.
C2: This value is a scaling value that should never be changed.
C3: The C3 value is the value that will change as a result of performing a
calibration on that cal set. This represents a mathematical value used to
calculate the yield, specific to that cal set.
The C values can be edited as described in the previous steps.
IMPORTANT: Do not change the C numbers after you have
calibrated. If you change the C number after calibration, the
accuracy of the monitor will be effected.