NATURAL G20
MAXIMUM HEAT INPUT 5kW
Thermostat Bypass 100 or 120
Main Burner Injector 285
Pilot Injector N35
Inlet Pressure 20mbar
PROPANE G31
MAXIMUM HEAT INPUT
5kW (357g/h)
Thermostat Bypass 60 or 80
Main Burner Injector 180
Pilot Injector L23
Inlet Pressure 37mbar
Burner Pressure 28mbar
Models GE Powered flue GE
ABCDEFGHJKLMNPQ S
mm
1487
967 851 679 41
1330
756
1125
39
3
698 65 375 48 595
R
116 667
DESN 511188
For natural gas the gas valve outlet pressure is non adjustable, BUT for reference purposes
only, a pressure drop of 1-2 mbar can be observed between inlet and outlet pressures on a
cold appliance.