Agatec DM100
Laser Distance Meter
3
14
25
36
47
58
Agatec DM100.book Page 1 Thursday, April 1, 2010 12:48 PM

Questions and Answers

  • A
    adavisAug 13, 2025
    What to do if there is a calculation error on Agatec DM100 Analytical Instruments?
    • T
      Tami RogersAug 13, 2025
      If you encounter a calculation error while using the Agatec Analytical Instruments, the suggested solution is to perform the measurement again. The cause of the problem is a calculation error.
  • M
    Michael WilkinsAug 17, 2025
    What to do if the laser beam is interrupted on Agatec DM100 Analytical Instruments?
    • L
      Lisa MartinAug 17, 2025
      If the laser beam is interrupted while using the Agatec Analytical Instruments, the suggested solution is to repeat the measurement. The cause of the problem is interruption of the laser beam.
  • J
    Jacob OliverAug 20, 2025
    What to do if the temperature is too high on Agatec Analytical Instruments?
    • M
      Mr. Michael Nguyen DVMAug 21, 2025
      If the temperature is too high when using the Agatec Analytical Instruments, let the device cool down. The cause of the problem is high temperature.
  • M
    Margaret SmithAug 25, 2025
    What to do if the temperature is too low on Agatec DM100 Analytical Instruments?
    • J
      jameshullAug 25, 2025
      If the temperature is too low when using the Agatec Analytical Instruments, warm the device up. The cause of the problem is low temperature.
  • S
    Sandra GrahamAug 28, 2025
    What to do if I get a measuring error due to too much background light on Agatec DM100?
    • R
      Richard Jones DDSAug 28, 2025
      If you are getting a measuring error because there is too much background light when using the Agatec Analytical Instruments, shadow the target area. The cause of the problem is too much background light.
  • D
    Denise LopezSep 1, 2025
    What to do if the reception signal is too weak or the measuring time is too long on Agatec DM100?
    • R
      Robin FrostSep 1, 2025
      If the reception signal is too weak, or the measuring time is too long when using the Agatec Analytical Instruments, change the target surface (e.g. white paper). This is because the reception signal is too weak, or the measuring time is too long.
  • A
    austinevansSep 4, 2025
    What to do if the input signal is too high on Agatec DM100 Analytical Instruments?
    • K
      Karina JosephSep 4, 2025
      If the input signal is too high when using the Agatec Analytical Instruments, change the target surface (e.g. white paper). The cause of the problem is high input signal.
  • M
    Matthew HillSep 8, 2025
    What to do if the measurement is outside of the measuring range on Agatec Analytical Instruments?
    • T
      Tina WilsonSep 9, 2025
      If the measurement is outside of the measuring range when using the Agatec Analytical Instruments, mind the range. The cause of the problem is that the measurement is outside of the measuring range.

Agatec DM100 Specifications

General IconGeneral
Accuracy±1.5 mm
Laser type635 nm, <1 mW
Operating temperature-10°C to +45°C
Protection classIP54
Weight100 g (including battery)
TypeLaser Distance Meter
Measuring range0.05 m to 100 m
Laser classClass II
Battery type2 x AAA
Measurement Range0.05 m to 100 m
Resolution1 mm
Light SourceLaser diode
DetectorPhotodiode
Power Supply2 x AAA batteries
Battery lifeUp to 5, 000 measurements