Agilent 53131A/132A/181A
225 MHz Counters
Assembly-Level
Service Guide
Manual Part Number 53131-90039
Printed in Malaysia
深圳德标仪器 135-1095-0799
Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 53131A and is the answer not in the manual?

Agilent Technologies 53131A Specifications

General IconGeneral
BrandAgilent Technologies
Model53131A
CategoryCash Counter
LanguageEnglish

Summary

Preface

How to Use This Guide

Information on navigating and utilizing the service guide effectively.

Repair Strategy

Guidance on the approach for isolating failures to the assembly level.

Instrument Identification

Details on identifying instruments using serial numbers and prefixes.

Instruments Covered by this Guide

Lists the specific Agilent models this service guide applies to.

Assembly-Level Service Guide Organization

Overview of the manual's structure, chapters, and content.

Description of the 225 MHz Counters

Provides an overview of the Agilent 53131A, 53132A, and 53181A counters.

Options

Lists available hardware and software options for the counters.

Support

Information on obtaining technical support and service.

Accessories Supplied and Available

Details on accessories provided with and available for the instrument.

Chapter 1 Performance Tests

Introduction

Overview of the procedures for testing instrument electrical performance.

Operational Verification

Abbreviated tests for confirming proper instrument operation.

Equipment Required

Lists the recommended test equipment for performance verification.

Agilent 53131 A;132 A;181 A Operational Verification

Step-by-step procedures for verifying basic instrument functionality.

Agilent 53131 A;132 A Complete Performance Tests

Detailed procedures to verify instrument specifications.

Agilent 53181 A Complete Performance Tests

Detailed procedures to verify instrument specifications for the 53181A model.

Chapter 2 Service

Introduction

Overview of the service information provided in this chapter.

Returning the Instrument to Agilent Technologies for Service

Instructions for preparing and shipping instruments for service.

About the Agilent 53131 A;132 A Calibration Menu

Reference information for the instrument's calibration menu.

The Agilent 53131 A;132 A Calibration Procedures

Step-by-step instructions for calibrating the instrument.

About the Agilent 53181 A Calibration Menu

Reference information for the Agilent 53181A's calibration menu.

The Agilent 53181 A Calibration Procedures

Step-by-step instructions for calibrating the Agilent 53181A.

Pre-Troubleshooting Information

Essential information including safety, test equipment, and repair advice.

Troubleshooting the Counter

Procedures for diagnosing and isolating counter faults.

Chapter 3 Replacing Assemblies

Introduction

Overview of the procedures for removing and installing major assemblies.

Tools Required

Lists the necessary tools for assembly replacement procedures.

To Remove the Cover

Detailed steps for removing the instrument's outer cover.

To Remove the Front Bezel

Instructions for removing the front bezel assembly.

To Remove A1 Motherboard Assembly

Procedure for removing the main motherboard assembly.

To Remove the A2 Display Board, Keypads, and Window

Procedure for removing the display board and associated components.

To Remove A3 1.5;3.0;5.0;12.4 GHz Channel Assembly (Option 015;030;050;124)

Procedure for removing optional channel assemblies.

To Remove A4 AC Power Supply Assembly

Procedure for removing the AC power supply assembly.

To Remove A5 DC Power Input Assembly (Option 002)

Procedure for removing the DC power input assembly.

To Remove A6 High Stability Timebase Assembly (Options 001, 010, and 012)

Procedure for removing high stability timebase assemblies.

To Remove the Rear Terminals (Option 060)

Procedure for removing rear terminal assemblies.

Chapter 4 Retrofitting Options

Introduction

Overview of the procedures for installing optional features.

Tools Required

Lists the necessary tools for retrofitting options.

To Retrofit A3 1.5;3.0;5.0;12.4 GHz Channel Assembly (Option 015;030;050;124)

Instructions for retrofitting optional channel assemblies.

To Retrofit A5 DC Power Input Assembly (Option 002)

Instructions for retrofitting the DC power input assembly.

To Retrofit A6 High Stability Timebase Assembly (Options 001, 010, and 012)

Instructions for retrofitting high stability timebase assemblies.

To Retrofit the Rear Terminals (Option 060)

Instructions for retrofitting rear terminal assemblies.

Chapter 5 Replaceable Parts

Introduction

Information related to ordering replacement parts.

Exchange Assemblies

Lists assemblies available for exchange.

Reference Designations

Explains reference designations used in parts lists and diagrams.

Replaceable Parts

Comprehensive list of all replaceable assemblies and parts.

How To Order A Part

Guides on identifying and ordering replacement parts.

Cabinet Parts and Hardware

Lists miscellaneous cabinet and chassis parts and hardware.

Chapter 6 Backdating

Introduction

Information to adapt the guide for older instrument versions.

Manual Changes

Information on adapting the guide based on serial prefixes.

Older Instruments

Guidance for adapting the manual for older counters.

Backdating Hardware

Specific hardware changes required for older models.

Backdating Firmware

Specific firmware changes required for older models.

Backdating Specifications

Specific specification changes required for older models.

Chapter 7 Agilent 53131 A;132 A Specifications

Introduction

Overview of the specifications for the Universal Counter.

Instrument Inputs

Details on the instrument's input specifications and characteristics.

Measurement Specifications (Continued)

Detailed specifications for various measurement functions.

Measurement Definitions

Definitions and explanations of systematic uncertainty terms.

Measurement Arming and Processing

Information on measurement arming modes and processing.

General Information

General product information including safety and interface details.

Chapter 8 Agilent 53181 A Specifications

Introduction

Overview of the specifications for the Frequency Counter.

Instrument Inputs

Details on the instrument's input specifications and characteristics.

Measurement Specifications (Continued)

Detailed specifications for various measurement functions.

Measurement Definitions

Definitions and explanations of systematic uncertainty terms.

Measurement Arming and Processing

Information on measurement arming modes and processing.

General Information

General product information including safety and interface details.