82 Principles of Operation
Table 4-1. Power Supply Interface Signals
Pin Signal Description
Output Power Connections
1
Busbar or terminal strip screw
terminals
+OUT
-OUT
Positive DC output voltage
Negative DC voltage (or return)
7-Pin I/O Analog Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
IP
VP
+Imon
-Imon
ÏP
+S
-S
Current Programming
Voltage Programming
External Current Monitor
External Current Monitor
Programming Common
+Sensing Terminal
2
-Sensing Terminal
Rx/Tx Serial Link (Used with GPIB Models 664xA and 665xA only)
3
J1 and J2 Connectors wired in
parallel (daisy chain fashion)
3-lines; Rx, Tx, and common signals for
both Jl and J2 connectors.
Jl and J2 are telephone connectors.
AC Input Power Source
AC power connector, J451 Can be 100 V AC, 120 V AC, 220 V AC or
240 V AC
Input AC power
TB101 Digital Control (DIG CNTL) for 664xA and 665xA Models only
Pins 1 through 4 Pins 1 through 4 can supply one of three
sets of signals
See Table 4-2 for these I/O signals
and pin destinations.
GPIB Interface Connector (Used With Agilent Models 664xA and 665xA only)
GPIB IEEE multi-pin connector signals. See
Chapter 6, Figure 6-3, Sheet 2 (Zone 8A)
for these signals.
IEEE 488 type connector provides
the interface between an external
computer and the GPIB board.
1
For the 500 watt Agilent 655xA and 665xA models, the +OUT and -OUT signals connect to bus-bar type, screw
terminals . For the 200 watt Agilent 654xA and 664xA models, these connections are made at a terminal strip on the
power supply.
2
A switch on the A1 Main Board selects either "Remote" sensing or "Local" sensing of the output voltages (+OUT and
-OUT) leads to be monitored.
3
The Rx and Tx serial link permits up to 16 Agilent power supplies to be connected in a daisy chain fashion, each with its
own unique programmed device address. One GPIB address with other units being subaddressed.

Table of Contents

Other manuals for Agilent Technologies 6541A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 6541A and is the answer not in the manual?

Agilent Technologies 6541A Specifications

General IconGeneral
BrandAgilent Technologies
Model6541A
CategoryPower Supply
LanguageEnglish

Related product manuals