1-44
Introduction
Commands Unavailable in Jitter Mode
Waveform Files Waveform and Color Grade/Gray Scale files cannot be saved or loaded in Jitter mode. The
commands listed below produce a "Settings conflict" error when executed in Jitter Mode.
DISK:STORe 10-9
When used with sources other than SETup and JDMemory.
STORe:WAVeform 4-14
ACQuire:SWAVeform 6-6
LTESt:SWAVeform 15-8
MTESt:SWAVeform 17-13
Waveform
Queries
Only jitter database waveforms may be set or queried in Jitter mode. Using the following com-
mand produces the error, "Signal or trigger source selection is not available".
:WAVeform:DATA 25-4
Waveform
Memory Load/
Store
Waveforms cannot be saved into waveform memories in Jitter mode. All waveform memories
are turned off when entering Jitter mode. The commands listed below produce a "Settings
conflict" error when executed in Jitter mode.
WMEMory<N>:LOAD 26-2
WMEMory<N>:SAVE 26-3
DISK:LOAD 10-4
When used with sources other than SETup and JDMemory.
WAveform
Memory Display
Waveform memories cannot be turned on in Jitter mode. The following command produces a
"Settings conflict" error when executed in Jitter mode.
WMEMory<N>:DISPlay 26-2
Waveform and
Color Grade-Gray
Scale Memory
The Waveform and Color Grade/Gray Scale memories cannot be turned on in Jitter mode. The
following command produces an "Illegal parameter value" error when executed in Jitter
mode.
VIEW 4-15
When used with arguments other than JDMemory.
Timebase Scale
And Delay
Scale and position controls on the Horizontal setup dialog are disabled in Jitter Mode. The fol-
lowing commands produce a "Settings conflict" error when executed in Jitter Mode:
TIMebase:RANGe 23-4
TIMebase:SCALe 23-5
TIMebase:POSition 23-2
Channel Scale
And Offset
Channel scale and offset controls are disabled in Jitter mode. The following commands pro-
duce a "Settings conflict" error when executed in Jitter Mode.
CHANnel<N>:OFFSet 8-4
CHANnel<N>:RANGe 8-6
CHANnel<N>:SCALe 8-6

Other manuals for Agilent Technologies 86100A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 86100A and is the answer not in the manual?

Agilent Technologies 86100A Specifications

General IconGeneral
BrandAgilent Technologies
Model86100A
CategoryTest Equipment
LanguageEnglish

Related product manuals