Measurement accessories
Accessories are available in these connector
types: 3.5 mm, 7 mm, 50-ohm type-N, 7-16, 75-ohm
type-N, and type-F. A standard 8753ES or one
equipped with Option 075 includes a built-in
S-parameter test set. A calibration kit and test-
port cables should be added for a complete meas-
urement system. For an 8753ES Option 011 net-
work analyzer, you also need to add a test set
or power splitter and bridge.
Test-port cables are used to connect to the device
under test. Calibration kits include standards,
such as open/short circuits and loads, which are
measured by the network analyzer for increased
measurement accuracy. Electronic calibration
(ECal) modules are used with the ECal interface
kit to provide automated calibration (in place of
a calibration kit). A verification kit is used in
conjunction with a calibration kit to verify system
performance.
50-ohm device measurements
Test-port cables
11857D
50-ohm 7-mm test-port return cables
A pair of phase-matched 610-mm (24 in) cables,
for use with the standard 8753ES network ana-
lyzer or the 85046A and 85047A test sets.
Option B24
Deletes phase-match requirement.
11851B
50-ohm type-N RF cable set
For systems based on an 8753ES Option 011.
Includes three phase-matched 610-mm (24 in)
cables and one 860-mm (34 in) cable. Used with
Agilent 11850C and 11667A power splitters.
Option B24
Deletes phase-match requirement.
Agilent part number 8120-5639
50-ohm type-N male to type-N male test-port cable
For use with the 8753ET.
Calibration kits
Choose a kit for each connector type to be used.
85031B
7-mm calibration kit
Contains fixed loads, and open/short circuit.
85032B
50-ohm type-N calibration kit
Contains fixed loads, open and short circuits,
and 7-mm to type-N adapters for both connector
sexes for use with 7-mm test-port cables.
Option 001
deletes 7-mm to type-N adapters
These adapters are not needed when this kit
is used exclusively with an 8753ET system.
85033D
3.5-mm calibration kit
Contains fixed loads, one-piece open and short
circuits, and 7-mm to 3.5-mm adapters for both
connector sexes for use with 7-mm test-port
cables.
Option 001
deletes 7-mm to 3.5-mm adapters
These adapters are not needed when this kit
is used exclusively with an 8753ET system.
Option 002
replaces 7-mm to 3.5-mm adapters with type-N
to 3.5-mm adapters
This option is recommended when the cali-
bration kit is used with the 8753ET.
85038A
7-16 calibration kit
Contains fixed loads, opens, and short circuits
in both connector sexes. Adapters not included
(see the “Adapters” section later in this guide
for information about the Agilent 11906 series
of 7-16 adapter kits).

Other manuals for Agilent Technologies 8753ET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8753ET and is the answer not in the manual?

Agilent Technologies 8753ET Specifications

General IconGeneral
BrandAgilent Technologies
Model8753ET
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals