Chapter 5 Error Messages
Execution Errors
128
-112 Program mnemonic too long
A command header was received which contained more than the maximum 12
characters allowed.
-113 Undefined header
A command was received that is not valid for this power supply. You may have
misspelled the command or it may not be a valid command. If you are using the short
form of the command, remember that it may contain up to four letters.
Example: TRIGG:DEL 3
-121 Invalid character in number
An invalid character was found in the number specified for a parameter value.
Example: *ESE #B01010102
-123 Numeric overflow
A numeric parameter was found whose exponent was larger than 32,000.
-124 Too many digits
A numeric parameter was found whose mantissa contained more than 255 digits,
excluding leading zeros.
-128 Numeric data not allowed
A numeric parameter was received but a character string was expected.
Example: DISP:TEXT 123
-131 Invalid suffix
A suffix was incorrectly specified for a numeric parameter. You may have misspelled
the suffix.
Example: TRIG:DEL 0.5 SECS
-134 Suffix too long
A suffix for a numeric parameter contained too many characters.
-138 Suffix not allowed
A suffix was received following a numeric parameter which does not accept a suffix.
Example: STAT:QUES:ENAB 18 SEC (SEC is not a valid suffix).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E3649A and is the answer not in the manual?

Agilent Technologies E3649A Specifications

General IconGeneral
BrandAgilent Technologies
ModelE3649A
CategoryPower Supply
LanguageEnglish

Related product manuals