ESG Family Signal Generators Hardkey and Softkey Reference
Utility
User’s Guide 4-135
Save User Preset
Use this softkey to establish your user-defined preset state. Set up all of
the instrument state conditions that you want for your unique preset
state. When you have defined the instrument state to suit your needs,
press
Save User Preset. Only one user-defined preset state is allowed, so
when you save the instrument state you will save over any
previously-saved state. Your instrument state will be recalled by the
signal generator any time you press
Preset as long as you have set the
Preset Normal User softkey to User. For additional information about the
Preset Normal User softkey, refer to its description in this section.
The user’s state definition is a state file; it is not affected by an
instrument preset or by a power cycle.
Softkey Location:
Utility > Power On/Preset > Save User Preset
SCPI
This softkey is one of the choices in both the Preset Language menu and
the Remote Language menu. Press either the
Preset Language softkey or
the
Remote Language softkey to view these menus. SCPI (Standard
Commands for Programmable Instruments) is the language chosen for
remote implementation of all supported instrument features. Choosing
SCPI in the Preset Language menu allows you to select this remote
language as the default after a normal preset. Choosing
SCPI in the
Remote Language menu allows you to immediately change the signal
generator to use this remote language.
Softkey Location:
Utility > Power On/Preset > Preset Language > SCPI
Or: Utility > GPIB/RS-232 > Remote Language > SCPI
Screen Saver Delay
This softkey sets the period of time before the screen saver is activated.
The screen saver delay is set to 1 hour at the factory. You can change
the delay by pressing
Utility > Display > Screen Saver Delay. The current
value for delay is displayed in the active entry area. To enter a new
value, rotate the front panel knob, use the up and down arrow keys, or
enter the value using the numeric keypad and press the
Enter
terminator softkey. The range of values allowed is 1 through 12 hours in
1 hour increments.
Screen saver delay is a persistent state; it is not affected by an
instrument preset or by a power cycle.
Softkey Location:
Utility > Display > Screen Saver Delay

Other manuals for Agilent Technologies E4437B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4437B and is the answer not in the manual?

Agilent Technologies E4437B Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4437B
CategoryPortable Generator
LanguageEnglish

Related product manuals