ESG Family Signal Generators Hardkey and Softkey Reference
Utility
User’s Guide 4-129
Preset Language
Pressing this softkey reveals a menu of choices for selecting the
programming language that is implemented after the
Preset key is
pressed. You can choose between SCPI, which is the language chosen
for the signal generator for remote implementation of all features,
8648-compatible, and four versions of 8656/57-compatible languages.
The 8648- and 8656/67-compatible languages are provided for remote
implementation of some features so that this signal generator can be
compatible with systems that use those instruments. Refer to the
programming guide for specifics on which commands are implemented.
The preset language is a persistent state; it is not affected by an
instrument preset or by a power cycle.
Softkey Location:
Utility > Power On/Preset > Preset Language
Preset Normal User
This softkey toggles the preset state between the factory-defined and
the user-defined states. You choose the instrument state conditions for
the user-defined preset state. Refer to the
Save User Preset softkey
description in this section.
The preset state is a persistent state; it is not changed by an
instrument preset or by a power cycle.
Softkey Location:
Utility > Power On/Preset > Preset Normal User
Proceed With Reconfiguration
Press this softkey to enable the selected hardware or software options.
In the Hardware Options menu, selected options are indicated by an X
in the column to the left of the option number. In the Software Options
menu, selected options include any options that have a license key
entered. After pressing this softkey, press the
Confirm Change softkey to
verify that you do want to reconfigure the signal generator with the
options that you have selected. If you do not want to continue, press the
Return key. Refer to Chapter 2, “Using Functions,” for an example of
using this function.
CAUTION If you enable an option that does not have the required hardware
installed, the menus for that option will be activated but the option
cannot operate, despite what the menus may seem to indicate.
Softkey Location:
Utility > Instrument Adjustments > Hardware Options >
Proceed With Reconfiguration
Or: Utility > Instrument Adjustments > Software Options >
Proceed With Reconfiguration

Other manuals for Agilent Technologies E4437B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4437B and is the answer not in the manual?

Agilent Technologies E4437B Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4437B
CategoryPortable Generator
LanguageEnglish

Related product manuals