term reliability of the frame.
It is strictly prohibited to repair or refit PV modules by yourself.
The surface of the touching photovoltaic module should be smooth, without sharp edges, burrs,
etc.
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities.
Contact your local government for information regarding the collection
systems available. If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the food chain,
damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated
to take back your old appliance for disposals at least free of charge.
3.6 Fire safety
Please consult local laws and regulations before installing PV modules, and comply with the
requirements on building fire resistance.
When installing on the roof, the roof must be covered with a layer of fireproof materials suitable
for this grade,and sufficient ventilation between the back plate and the installation surface must be
ensured.
Different roof structures and installation methods will affect the fire safety performance of
buildings. Improper installation may cause fire.
In order to ensure the fire rating on the roof, the minimum distance between the PV module
frame and the roof surface is 10cm.
Please use appropriate PV module accessories such as fuse, circuit breaker and grounding
connector according to local regulations.
Do not use PV modules if exposed flammable gases are present nearby.